Viking E-70 Series Скачать руководство пользователя страница 8

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

Fax Back Doc 207

ZF302850 Rev 3

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

8

B. One E-70 Sharing a Single Line with Optional Call Forwarding and Doorstrike/Gate Control

LED1

S1

C

LED3 LED2

C

C

1

3

2

ON

POWER

13.8 V

A

C

1  2  3

1

2 3

4

5

6

7

8

9 10 11 12

LINE IN

EARTH GND

DOOR

STRIKE

TRIGGER

INPUT

NC

NO

COM

ENTR

Y

PHONES

AUT

ANSWER

TRIGGER MODE

LEARN MODE

POWER

CALLING

VIKING

ELECTRONICS

HUDSON, WI 54016

ENTRY CONTROLLER

WITH CALL FORWARD

MODEL C-250

©

VIKING

C.O. Line

House Phones

Postal Lock
Switch (N.O.)

Model E-70-SS shown 

* Earth Ground

(N.C.)

13.8V AC

Adapter

included

120V AC

Doorstrike/

Magnetic Lock

120V AC

OR

Auto Call Forward

Switch (N.O.)/Timer

To Viking ES-1 or Equivalent

Wiegand Door Controller (see page 6)

* Note:

To increase surge protection, fasten a wire

from the screw terminal to Earth Ground (grounding
rod, water pipe, etc.)

Model C-250 (not included)

For more information on
the C-200, see DOD# 172.

C. Sharing a Single E-70 with an Existing Phone Line

SINGLE ENTRY PHONE

CONTROLLER

VIKING

©

MODEL C-200

PWR 13.8 V

AC

AUX RELA

Y

CONT

ACT

S

1

2

3

4

5

8

9 10

EARTH

GND 

PHONE LINE

INPUT

LINE OUT

TO PHONES

6

7

TO ENTRY

 PHONE

VIKING

ELECTRONICS

HUDSON, WI 54016

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

ENTRY
PHONE

N.O.   COM   N.C.
AUX CONTACTS

ON

 1     2     3

11 12

AUX POWER

 OUTPUT

AUX POWER

OUTPUT

RING COUNT

RELAY MODE

DOORBELL MODE 

* Earth Ground

(optional)

E-70-BN shown

13.8V AC

Adapter

included

120V AC

Entry Door
Phone

Standard

Analog Phone(s)

-OR-

Analog Trunk / Line

Input of a Phone System

C.O. / Phone

Line Input

N.O. contacts to doorbell
switch, camera control, etc.

To Viking ES-1 or 
Equivalent Wiegand
Door Controller
(see page 6)

Wiegand

Output

* Note:

To increase surge protection,

fasten a wire from the screw terminal
to Earth Ground (grounding rod,
water pipe, etc.)

Model C-200 (not included)

For more information on
the C-200, see DOD# 169.

Содержание E-70 Series

Страница 1: ...owder coating excludes E 70 SS stainless steel faceplate Vandal Resistant Features 16 gauge polished brass or 18 gauge stainless steel faceplate stainless steel push button stainless steel speaker scr...

Страница 2: ...ing call In most but not all areas the sum of the REN s should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as deter mined by the total REN s contact the...

Страница 3: ...ection D Step 6 To maintain a vapor barrier on outside wall applications caulk around the box filling any gaps between the box and the rough opening Apply caulk to any holes in the box around wires et...

Страница 4: ...otector be installed to protect against such surges Contact Panamax at 800 472 5555 or Electronic Specialists Inc at 800 225 4876 Circuit Board Mounting Plate included 1 4 Thick Foam Faceplate Gasket...

Страница 5: ...ot be heard over the speaker A microphone volume pot is pro vided for increasing or decreasing the microphone volume Note If the microphone volume is set too high or too low one way talk path may occu...

Страница 6: ...s factory set to 111 0 3 secs Forced hang up command used to exit programming and hang up the E 70 0 00 000 0000 111 111 111 Select Feature beep beep beep 3 beeps Wait for Beep s Enter Time Value beep...

Страница 7: ...ENTRY PHONE 4 DOOR STRIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT Entry Phone 1 E 65 SS shown Example Front Door C O Phone Line Input To...

Страница 8: ...included 120V AC Doorstrike Magnetic Lock 120V AC OR Auto Call Forward Switch N O Timer To Viking ES 1 or Equivalent Wiegand Door Controller see page 6 Note To increase surge protection fasten a wire...

Отзывы: