![Viking E-70 Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/viking/e-70-series/e-70-series_technical-practice_1024541004.webp)
VIKING
Model:
XXXXXXX
xxxxxx
S/N:
REN 0.8A:
XXXXXXXX
V
iking Electronics, Inc. (715) 386-8861
1531 Industrial St., Hudson, WI 54016
P/N:
DEV
:
Complies with FCC Part 15 and 68 Reg. No: US:AH3TE08
A22264
LED3
LED1
LED2
LED4
LED5
LED6
LED7
C
C
C
C
C
C
C
J11-
1
2
3
J10-
1
2
3
J9-
1
2
3
J8-
1
2
3
J7-
1
2
3
12
3
on
4
5
VIKING
©
MODEL C-2000B
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 1 0 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PWR 13.8 V
A
C
EARTH GND
ENTR
Y
PHONE 1
DOOR STRIKE 1
ENTR
Y
PHONE 2
DOOR STRIKE 2
ENTR
Y
PHONE 3
DOOR STRIKE 3
ENTR
Y
PHONE 4
DOOR STRIKE 4
DOORBELL
SWITCH /
AUX. INPUT
AUX. CONT
ACT
OUTPUT
PHONE LINE
INPUT
LINE OUT
T
O
PHONES
ANALOG ST
A
T
ION
INPUT
VIKING
©
DLE-200B
RES
RINGDOWN
BUSY
1
2
VIKING
©
Programmable
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
∗
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
Viking Electronics, Inc.
Hudson, WI 54016
LINE IN PHONE
Red
(Ring)
Green
(Tip)
** Earth
Ground
(optional)
(Ring
connector
included)
Rear View of the
E-70 Circuit Board
Mounting Plate
-or-
* Gel-Filled
Butt Connectors
(included)
E-70 is not
polarity sensitive
Viking C-200, C-250 or C-2000B Entry
Phone Controller (not included)
*** Optional Viking
K-1900-5 Dialer
(not included)
**** C.O. Line
or Analog
PABX/KSU Station
(programmed for
ringdown)
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
*** Note:
Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking Hot-Line Dialer. For more info, retrieve
Fax Back Documents 833
.
** Note:
To increase surge protection, loosen the PCB mounting screw labeled (as shown above) and fasten a wire with ring terminal (included) from the mount-
ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.
* Note:
The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of
0.082 inches. Do not strip wires prior to terminating.
**** Note:
When installing a line powered phone on a low voltage and/or low loop current phone system exten-
sion, a Viking
TBB-1
Talk Battery Booster may be required.
?
Need More Information on the PS-2R?
Call (715) 386-4345 and select 512.
E. Wiring the E-70 Phone Board
IMPORTANT:
Electronic devices are susceptible to lightning and power station electrical surges from both
the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect
against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
Circuit Board
Mounting Plate
(included)
1/4" Thick Foam
Faceplate Gasket
(included)
Facplate
(included)
(4) 6-32 x 1.25" Long
5/64" Hexdrive
Flathead Screws
(included)
"Old Work" Double Gang Rough-In
Box with minimum dimensions of:
3.7"W x 2.84"H x 2.25"D. (Carlon
BH234R box shown, not included)
Optional VE-5x5 Surface Mount Box
with Black Satin Powder Paint Finish,
not included (DOD# 424) WARNING:
Do NOT use a wet location box.
Optional VE-LIGHT Kit can be used
to illuminate the E-70 faceplate,
see DOD# 428.
2.25”
5.14”
5.22”
3.25”
3.63”
3.63”
-OR-
(2) Junction Box to
Double Gang Adapter
Plates and (4) 5/64 Hex
Drive Flat Head Screws
(included with the E-70)
*2.25"
Deep
Min.
** LED
Light Pipe
(included)
(9) 3-Wire Gel-Filled
Butt Connectors
(included)
Green
Red
Wires from
Phone Board
W/BL
BL/W
Wing Brackets
Belden
9537
Cable
Wires from Prox
Card Reader
Black
Red
Black
Red
Green
White
Green
White
CAT5E
Cable
C. Surface Mounting
D. Mounting the Faceplate
A Viking model
VE-5x5
can be used to surface mount an
E-70
to a wall or post. Recommended mounting height to bot-
tom of
VE-5x5
is 50” - 54”. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or
caulking. Route wire into the
VE-5x5
box, securely screw it to wall or post and seal hole in box around wire with putty
or caulking.
Note:
Conduit may also be used when surface mounting wire, but should not enter through the top of the
VE-5x5
. When routing wiring from above, a drip loop is required.
WARNING:
Do
NOT
use a typical “wet location box”
as not all styles seal properly with the
E-70
faceplate.
After the Rough-In box or
VE-5x5
is securely mounted, caulking between the box and rough opening is completed (if
required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section
G
).
Remove paper liner from face plate gasket and place it on back side of face plate aligning with push button hole. Push
the 1-1/4" 6-32 screws through faceplate holes and small holes in gasket, the faceplate gasket should retain the
screws. Position the circuit board mounting plate over screws. Align screws with single gang box bosses and tighten
face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate.
Included 1/4" thick gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick,
stucco, etc.) additional caulking may be required.
4
* CAUTION:
Excessive wire length and/or using a
rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.
** Important:
Push LED light pipe into faceplate hole, then place face-
plate upside down on a clean flat surface and push down on back side
of plate until light pipe is fully seated and straight.
WARNING:
Inserting
the light pipe more than one time can cause a loose fit.