VIKING
©
DLE-200B
RES
RINGDOWN
BUSY
1
2
VIKING
©
Programmable
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
∗
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
Viking Electronics, Inc.
Hudson, WI 54016
LINE IN PHONE
Red
(Ring)
Green
(Tip)
** Earth
Ground
(optional)
(Ring
connector
included)
Back View of the
E-50 Circuit Board
Mounting Plate
VIKING
©
MODEL C-2000A
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5
6 7 8 9 10
11 12 13 14 15
16 17 18 19 20
21 22 23 24 25
26 27 28 29 30
PWR 13.8 V
A
C
EARTH GND
ENTR
Y
PHONE 1
DOOR STRIKE 1
ENTR
Y
PHONE 2
DOOR STRIKE 2
ENTR
Y
PHONE 3
DOOR STRIKE 3
ENTR
Y
PHONE 4
DOOR STRIKE 4
DOORBELL
SWITCH /
AUX. INPUT
AUX. CONT
ACT
OUTPUT
PHONE LINE
INPUT
LINE OUT
T
O
PHONES
* 3-Wire Gel-Filled
Butt Connectors
(included) E-50
phone board is not
polarity sensitive
Viking C-2000A 1-4 Entry Phone
Controller
(not included)
(see Application section B, page 8)
*** Optional Viking
K-1900-5 Dialer
(not included)
**** C.O. Line or Analog
PABX/KSU Station
(programmed for ringdown)
Viking DLE-200B
Two Way Ringdown
Circuit
(not included)
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
SINGLE ENTRY PHONE
CONTROLLER
VIKING
©
MODEL C-200
P
W
R
1
3
.8
V
A
C
A
U
X
R
E
L
A
Y
C
O
N
T
A
C
T
S
1
2
3
4
5
6
7
8
9 10
EARTH
GND
PHONE LINE
INPUT
LINE OUT
TO PHONES
TO ENTRY
PHONE
VIKING
ELECTRONICS
HUDSON, WI 54016
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
ENTRY
PHONE
N.O. COM N.C.
AUX CONTACTS
ON
1 2 3
Viking C-200 Single Entry
Phone Controller
(not included)
(see Application section A, page 7)
-or-
To C.O. Line or
PABX/KSU station
*** Note:
Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking Hot-Line Dialer. For more info, retrieve
Fax Back Documents 833
.
** Note:
To increase surge protection, loosen the PCB mounting screw labeled (as shown above) and fasten a wire with ring terminal (included) from the mount-
ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.
* Note:
The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of
0.082 inches. Do not strip wires prior to terminating.
**** Note:
When installing a line powered phone on a low voltage and/or low loop current phone system exten-
sion, a Viking
TBB-1
Talk Battery Booster may be required.
?
Need More Information on the PS-2R?
Call (715) 386-4345 and select 512.
E. Wiring the E-50 Phone Board
IMPORTANT:
Electronic devices are susceptible to lightning and power station electrical surges from both
the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect
against such surges. Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
!
(5) 3-Wire Gel-Filled
Butt Connectors
(included)
"Old Work" Rough-In Box
(Allied Molded 9331 box
shown, not included)
Circuit Board
Mounting Plate
(included)
1/4" Thick Foam
Faceplate Gasket
(included)
Facplate
(included)
Green
Red
(2) 6-32 x 1.25" Long
5/64" Hexdrive Flathead
Screws (included)
4.875"
3.125"
(4) Optional Dry
Wall Screws
(not included)
Optional
Mounting Ears
Optional Wing
Brackets
*2.25"
Deep
Min.
Optional VE-3x5 Surface Mount
Box with Black Satin Powder Paint
Finish (not included) WARNING: Do
NOT use a wet location box.
1.8"
3.17"
4.92"
-OR-
Conduit Knockout
Condensation
Drain Hole
Wires from
Phone Board
Wires from
Camera
Red
Black
Yellow
CAT5E
Cable
2.00"
Wide
Min.
W/BL
BL/W
O/W
W/O
G/W
W/G
2.84"
Tall Min.
C. Surface Mounting
D. Mounting the Faceplate
A Viking model
VE-3x5
can be used to surface mount an
E-50
to a wall or post. Recommended mounting height to bot-
tom of
VE-3x5
is 50” - 54”. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or
caulking. Route wire into the
VE-3x5
box, securely screw it to wall or post and seal hole in box around wire with putty
or caulking.
Note:
Conduit may also be used when surface mounting wire, but should not enter through the top of the
VE-3x5
. When routing wiring from above, a drip loop is required.
WARNING:
Do
NOT
use a typical “wet location box”
as not all styles seal properly with the
E-50
faceplate.
After the Rough-In box or
VE-3x5
is securely mounted, caulking between the box and rough opening is completed (if
required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section
G
).
Remove paper liner from face plate gasket and place it on back side of face plate aligning with push button hole. Push
the 1-1/4" 6-32 screws through faceplate holes and small holes in gasket, the faceplate gasket should retain the
screws. Position the circuit board mounting plate over screws. Align screws with single gang box bosses and tighten
face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate.
Included 1/4" thick gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick,
stucco, etc.) additional caulking may be required.
4
* CAUTION:
Excessive wire length and/or using a rough-in box with inadequate depth can apply
force to the circuit board causing physical damage.