13
12
2
1
1
x4
1
2
2
x4
x4
x4
Remove rear cover.
Attach damper.
3
4
Check damper for unrestricted
movement, adjust if necessary.
Attach the
optional and locally supplied
transition to
damper. Seal with aluminum tape.
3
5
1
2
x2
1
6
2
Flip hood over and remove blower.
Remove recirculating bracket and turn blower around.
Installation
(Rear duct)
1
7
2
x2
8
Reinstall blower. Ensure that blower
opening faces the rear of the hood.
Remove electrical box cover.
1
9
2
Insert 6” of electrical wiring through the top of vent hood
and secure using wiring restrain. Refer to local codes.
10
11
5/16”
nut driver
Slide duct over transition and tape around joint.
CAUTION:
Secure vent hood to wall
using screws provided. Use additional mounting
screws and wall anchors, if necessary.
Installation
(Rear duct cont.)
W A R N I N G
To reduce the risk of fire, electric shock, or
injury to persons, observe the following:
• Use this unit only in the manner intended
by the manufacturer. If you have any
questions, contact the manufacturer.
• Before servicing or cleaning unit, switch
power off at service panel and lock service
panel to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning
device, such as a tag, to the service panel.