Disassembly
©2010 Viking Preferred Service
27
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Convection Bake Element Removal
Condition Requirements:
Convection Fan Cover Removed
1. Remove screws that attach the convection bake
element to the oven liner.
2. Mark and disconnect wires from convection element.
3. Reverse procedure for installation.
Broil Element Removal
Condition Requirements:
Door Assembly Removed
1. Remove screws and bracket from broil assembly.
2. Remove screws that hold the broil assembly to the
back of the oven liner.
3. Remove screws that hold the broil assembly to the
top of the oven liner.
Note:
Use care when pulling broil assembly into the
oven cavity. Make sure the connectors remain
on the broil assembly.
4. Carefully pull connectors through the oven cavity wall
and lower the broil assembly.
5. Mark and disconnect connectors from broil element.
Note:
During installation, make sure broil connectors
go back through the oven liner.
6. Reverse procedure for installation.
Control Components Accessed
Condition Requirements:
Door Assembly Removed
1. Remove all surface burner knobs.
2. Remove screws from control panel assembly where
knobs have been removed.
3. Remove screws from below control panel assembly.
4. Lift up to remove control panel assembly from
keyhole screws.
5. Place control panel assembly on protective surface
on the top of range.
6. Reverse procedure for installation.
Control Panel Assembly Removal
Condition Requirements:
Control Components Accessed
1. Mark and disconnect all connectors to remove control
panel from range.
2. Reverse procedure for installation.