Viking DMOR206 Скачать руководство пользователя страница 1

Mounting Space

This Convection Microwave Hood requires a mounting 
space on a wall as shown in figure 

1

. It is designed to 

be used with standard 12-inch wall cabinets.

For proper installation and servicing, a 2-inch space is 
necessary between the top of the range backguard and 
the bottom of the Convection Microwave Hood.

Wall Construction

This Convection Microwave Hood should be mounted 
against and supported by a flat vertical wall. The wall 
must be flat for proper installation. If the wall is not flat, 
use spacers to fill in the gaps. Wall construction should 
be a minimum of 2" x 4" wood studding and 3/8" or more 
thick dry wall or plaster/lath. The mounting surfaces must 
be capable of supporting a weight of 110 pounds—the 
oven and contents—AND the weight of all items which 
would normally be stored in the top cabinet above the 
unit.

The unit should be attached to a minimum of one 2" x 
4" wall stud or two 2" x 3" wall studs.

To find the location of the studs, one of the following 
methods may be used:

• 

Use a stud finder, a magnetic device which locates the 
nails in the stud.

• 

Use  a  hammer  to  tap  lightly  across  the  mounting 
surface to find a solid sound. This will indicate stud 
location. 

The center of the stud can be located by probing the 
wall with a small nail to find the edges of the stud and 
then placing a mark halfway between the edges. The 
center of any adjacent studs will normally be 16" or 24" 
to either side of this mark.

Viking Installation Guide

Convection Microwave Hood

111 Front Street

Greenwood, Mississippi 38930 USA

IMPORTANT–Please Read and Follow!

• 

Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are 
recommended to install this product.

• 

If a new electrical outlet is required, its installation should be completed by a qualified electrician before the 
Convection Microwave Hood is installed. See 3 ELECTRICAL GROUNDING INSTRUCTIONS on page 2.

Backguard

At least 2"

15.5"

30"

12"

36" or more 

from cooking 

surface

72" or more 

from floor

1

Содержание DMOR206

Страница 1: ...ud or two 2 x 3 wall studs To find the location of the studs one of the following methods may be used Use a stud finder a magnetic device which locates the nails in the stud Use a hammer to tap lightl...

Страница 2: ...an 140 feet This appliance must be grounded This oven is equipped with a cord having a grounding wire with a grounding plug It must be plugged into a wall receptacle that is properly installed and gro...

Страница 3: ...13 2 amps CSA Rating 1 5 kw 13 0 amps Approx Shipping Wt 71 lbs 32 2 kg Parts shown not to common scale The INSTALLATION HARDWARE items 1 7 packed with the oven should contain the following Item Part...

Страница 4: ...rcoal Filter included with the unit is required for recirculating exhaust B Horizontal Exhaust Outside Ventilation HORIZONTAL EXHAUST Remove and save 4 screws Remove fan cover bracket figure figure fi...

Страница 5: ...ion Remove and save 4 screws and fan cover bracket as shown in figure 5 Withdraw hood fan unit See figure 6 A B figure figure figure figure figure figure figure figure A Rotate 90 VERTICAL EXHAUST Rot...

Страница 6: ...oggle Nuts and Bolts through the holes in the wall with the Toggle Nuts closed Use Wood Screws to attach the Mounting Plate to studs Space more than wall thickness Wall Note Before insertion be sure y...

Страница 7: ...r back edge of the oven with the mounting plate Thread the power supply cord through the hole made in the bottom of the top cabinet B B C D figure figure figure figure figure figure figure figure MOUN...

Страница 8: ...r visit the Viking Web site at vikingrange com TINSEB505MRR1 F20380 Oven Installation B C D figure figure figure figure MOUNTING OVEN TO THE WALL Install Grease Filters by fitting into the opening Pus...

Страница 9: ...2 po x de 3 po Pour trouver l endroit des goujons un des m thodes suivantes peut tre employ Utilisez un trouveur de goujon un dispositif magn tique qui localise les ongles dans le goujon Utilisez un m...

Страница 10: ...re fondu Ce four est quip d une corde ayant un fil de masse avec une prise fondante Il doit tre branch une prise murale qui est correctement install e et fondue selon le code lectrique national et les...

Страница 11: ...nt si n cessaire Le MAT RIEL D INSTALLATION points 1 7 emball avec le four devrait contenir ce qui suit Article De Part Nom Code Quantit 1 Vis en bois 5 x 30 millim tres XTSS750P35000 6 2 Boulon bascu...

Страница 12: ...sch ma sch ma sch ma sch ma sch ma sch ma sch ma sch ma sch ma Coude 90 10 pi Coude 45 5 pi Adaptateur 5 pi Chapeau mur 40 pi Chapeau toit 24 pi Coude de 10 10 pi Coude 25 25 pi Coude 45 5 pi l on a...

Страница 13: ...ATION serrent dans l endroit C chappement Vertical Ventilation Ext rieure Enlevez et sauvez 4 parenth ses de vis et de couverture de ventilateur comme repr sent sur le sch ma 5 Retirez l unit de venti...

Страница 14: ...SUPPORT Placez le plat de support avec les boulons bascule attach s l endroit de mur et passez les crous et les boulons bascule dans les trous dans le mur avec les crous bascule ferm s Utilisez les vi...

Страница 15: ...splash jusqu ce qu il s arr te Alignez le bord arri re inf rieur du four avec le plat de support B B C D sch ma sch ma sch ma sch ma sch ma sch ma sch ma sch ma Four de support au mur Accrochez le fou...

Страница 16: ...consulter notre site Web vikingrange com TINSEB505MRR1 F20380 Installation de Four B C D sch ma sch ma sch ma sch ma MONTER LE MUR DE FOUR Installez les filtres de graisse par le raccord sur l ouvertu...

Страница 17: ...ara encontrar la ubicaci n de los montantes puede seguir uno de los siguientes m todos Utilice un localizador de montantes un dispositivo magn tico que localiza los clavos en el montante Utilice un ma...

Страница 18: ...re a tierra y un enchufe con conexi n a tierra Debe conectarse en un tomacorriente de pared instalado y conectado a tierra apropiadamente de acuerdo con el C digo El ctrico Nacional y los c digos y re...

Страница 19: ...de escape si es necesario Pa o protector de ca das para el aparato y el horno tambi n puede utilizar cart n Tijeras Cinta m trica L piz Cinta Especificaciones B sicas Horno Microondas Descripci n VMO...

Страница 20: ...ra figura figura igura igura 90 Codo 10 pies 90 Codo 25 pies 45 Codo 5 pies 45 Codo 5 pies Adaptador 5 pies Tapa de Pared 40 pies Codo Ancho de 10 pulgadas 10 pies Tapa de Techo 24 pies Soporte de la...

Страница 21: ...tracci n Hacia el Exterior Retire y guarde los 4 tornillos y el soporte de la cubierta del ventilador como se muestra en la figura 5 Retire la unidad de ventilador de la campana Vea la figura 6 A B fi...

Страница 22: ...ernos acodados en los agujeros de la pared con las tuercas acodadas cerradas Utilice tornillos para madera para fijar la placa de montaje a los montantes Espaciar m s que el espesor de la pared Pared...

Страница 23: ...tope posterior hasta que se detenga Alinee el borde posterior inferior del horno con la placa de montaje B B C D figura figura figura figura figura figura figura figura MONTAJE DEL HORNO A LA PARED P...

Страница 24: ...itio Web de Viking en vikingrange com TINSEB505MRR1 F20380 B C D figura figura figura figura MONTAJE DEL HORNO A LA PARED Instale los filtros de grasa encaj ndolos en la abertura Presione hacia atr s...