5

Door Swing Pin (Flush head, 1/8” allen drive)

Top Hinge
Bracket

Bottom Hinge
Bracket

Door Swing Pin
(Round head, Phillips)

Light Switch Activator

AREA REQUIREMENTS

Units Certified for Indoor Use - (black outer cabinet)

MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR
DRIP).
1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front 

MUST BE

unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 55°F (13°C) and below 110°F (43°C).  Best results

are obtained at temperatures between 65°F (18°C) and 80°F (27°C) for built-in products and 65°F (18°C) and 90°F
(32°C) for freestanding products.

3.  Provisions for electricity should be determined before placing unit in proper place.

Units Certified for Outdoor Use - (stainless steel outer cabinet)

1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front 

MUST BE

unobstructed for air circulation and proper operation.

Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 40°F (4.4°C) and below 110°F (43°C).  Best results

are obtained at temperatures between 60°F (16°C) and 100°F (38°C).

3.  Provisions for electricity should be determined before placing unit in proper place.

REVERSIBLE DOOR 
Professional Series
(Glass Door Units Only)

You can change the door swing from right to left hinge very easily.
1.  Simply unscrew the top hinge door swing pin with an 1/8”

allen drive unit and lift door off of the bottom hinge bracket.
Flip the door, remove the light switch activator and replace the
light switch activator on the other end of the door.

2.  Remove the door swing pin from bottom right hinge. Move the

bottom, right hinge bracket to the upper, left side of the
cabinet and fasten it in place with its original mounting screws.  

3.  Install the hinge door swing pin into the top right hinge bracket

and move the bracket to the lower left side of the cabinet.
Fasten it in place with its original screws.  

4.  Place the plastic washer over the bottom door swing pin on

the top surface of the bottom, left hinge.  

5.  Position the door on the bottom, left hinge pin and push the

door under the top, left hinge.  

6.  Line-up the top left hinge hole with the door bushing hole and

insert swing pin. Screw down the door swing pin with the 1/8”
allen drive unit until its head is flush with the top surface of the
top, left hinge.  

7.  Reposition the logo. Your installation is now complete.

GENERAL INFORMATION

Unpack

1.  Remove banding from bottom of carton.  Lift carton up and off of the unit.
2.  Remove all tape and packaging material from the outside and inside of the cabinet.
3.  Keep all carton packaging until your refrigerated beverage center has been thoroughly inspected and found to be in

good condition.

4

SPECIFICATIONS/DIMENSIONS
DESIGNER SERIES

Basic Electric Data

•115 VAC/60 Hz
•Maximum amps - 3.3
•Approximate shipping weight - 140 lbs (63.2 kg)

Front View

30 3/4”

(78.1 cm)

Mín. 

34 1/4” 

(87.0 cm)

Max.

35”

(88.9 cm)

with leveling

legs fully

extended

23 7/8” (60.6 cm)

Side View
DUAR

22” (55.9 cm)

24 3/8” (61.9 cm) 

25 3/8” ( 64.5 cm)

47 1/4” (120.0 cm)

Side View
DFUR

22” (55.9 cm)

24 3/16” (61.4 cm) 

47 1/4” (120.0 cm)

(to front of locally supplied

custom panel

Содержание DFUR

Страница 1: ...Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Use Installation Guide 24 Wide Undercounter Freestanding Refrigerated Beverage Center ...

Страница 2: ...SE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION It is your responsibility to be sure your refrigerated beverage center is located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the cor...

Страница 3: ...e the door swing from right to left hinge very easily 1 Simply unscrew the top hinge door swing pin with an 1 8 allen drive unit and lift door off of the bottom hinge bracket Flip the door remove the light switch activator and replace the light switch activator on the other end of the door 2 Remove the door swing pin from bottom right hinge Move the bottom right hinge bracket to the upper left sid...

Страница 4: ... bottom door hinge brackets to the door with the 10 32 machine screws and a 1 8 allen head driver as shown in Figure 1 below 2 Press in the shoulder bushings to the top and bottom door hinge brackets Make certain that the shoulder is to the outside of the door as shown in Figure 1 below 3 Test fit the door to the unit to make certain door will hang correctly The door is hung correctly when the top...

Страница 5: ... from front to back and side to side If floor conditions do not allow the unit to sit level adjust the leg leveler by turning the required leg leveler counter clockwise to increase the height and clockwise to reduce the height Leg Leveler 4 per unit Weldnut Each bottom corner of unit 8 Attaching the Wood Frame to the Door DFUR MODEL 1 If the door is attached to the unit remove by unscrewing the to...

Страница 6: ...unit Initially set the control knob midway between the numbers Allow at least 48 hours for the unit to stabilize before making any adjustments to the initial setting FOR OUTDOOR UNITS it is recommended that in temperatures above 110o F 43o C and below 40o F 4 4o C the unit be shut off The normal operating range for the unit is between 60o F 15 6o C and 100o F 37 7o C General Tips and Suggestions A...

Страница 7: ...ibrates Cabinet not level weak floor Cabinet light not working Bulb burned out no power at outlet Appliance will not run Temperature control to OFF line cord not plugged in no power at electrical outlet house fuse blown Appliance runs too long Prolonged door openings control set too cold condenser needs cleaning Moisture collects inside Too many door openings prolonged door openings hot humid weat...

Страница 8: ... apply to you This warranty gives you specific rights and you may also have other rights which may vary from jurisdiction to jurisdiction Specifications subject to change without notice 14 BUILT IN UNDERCOUNTER FREESTANDING REFRIGERATED BEVERAGE CENTER WARRANTY Units certified for Outdoor Use ONE YEAR FULL WARRANTY Built in freestanding undercounter refrigerated beverage centers and all of their c...