© 20
10
Viking Preferred Service
71
Service Diagnostics and Procedures
Cavity Cover Assembly
1. Remove screws securing upper dispenser.
2. Disconnect wiring harness and remove cavity
cover.
3. Replace switch assembly if necessary.
4. Reverse procedure to reinstall.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Upper Dispenser
Wiring Harness
Switch Assembly
Содержание DFSB542 Series
Страница 81: ...2010 Viking Preferred Service 81 Wiring and Schematics Schematic Ice and Water Dispenser before 5 19 2010...
Страница 83: ...Wiring and Schematics 2010 Viking Preferred Service 83 Schematic Ice and Water Dispenser after 5 19 2010...
Страница 86: ...Wiring and Schematics 2010 Viking Preferred Service 86 Wiring Diagram with Dispenser After 5 19 2010...