background image

19

Cooktop

Bracket

Screw

Countertop

1

Cooktop

Bracket

Countertop

Eye Bolt

2

Screw hold down brackets using the #10 x 1/2” sheet

metal screw to the burner box.

Screw the eye bolt into the self-retaining nut and

tighten firmly against bottom of countertop.

Cooktop

Bracket

Countertop

1

Cooktop

Bracket

Countertop

2

Place a bracket in the slots and lower

until the bracket catches.

Use the bolt to tighten the cooktop to the countertop.

Note:

There must be a 1” (2.5 cm) clearance under

counter on all four sides of cooktop.

DGSU Bracket Installation

VGSU Bracket Installation

18

2

2

2

2

1

1

1

2

Optional Gasket

Remove the grates and burner caps.

Turn the cooktop upside down and place on a non-

scratch surface.

Note:

Make sure there are no loose

objects on the cooktop before turning upside down.

3

Optional Gasket

4

Note:

Refer to

“Electrical & Gas

Requirements”

section for

proper

installation

information.

1

Installation

Peel away the plastic covering and place the gasket

material all the way around the burner flange.

IMPORTANT:

Make sure the corners are covered

completely, leaving no air gaps.

Turn the cooktop over and place into countertop

opening.

Gas & Electrical Connection

Содержание Designer DGSU1605BSS

Страница 1: ...and Designer Built In Gas Cooktops Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web si...

Страница 2: ...COULD result in minor personal injury or property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are...

Страница 3: ...if a gas leak occurs Formaldehyde and soot are byproducts of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion WARNING ELECTRI...

Страница 4: ...st be physically changed Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP Uses standard residential 1 2 1 3 cm I D gas service line Electrical requirements 120 VAC 60 H...

Страница 5: ...uds and regulator must be physically changed Order conversion kit DLPK to convert to LP Uses standard residential 1 2 1 3 cm I D gas service line Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3...

Страница 6: ...m max B 19 3 4 50 2 cm C 2 1 2 6 4 cm 36 min 91 4 cm 28 1 8 71 4 cm 5 12 7 cm max toe kick 28 1 2 72 4 cm 2 6 7 8 7 3 3 c m 2 1 2 6 4 c m m i n 1 2 1 4 3 1 1 c m 1 4 5 8 3 7 2 c m 14 1 4 36 2 cm 14 1...

Страница 7: ...djacent Combustible Construction Above countertop 36 91 4 cm minimum Side 8 20 3 cm Rear o VGSU 2 1 2 6 4 cm min o DGSU 2 1 2 6 4 cm min Within 6 side clearance Wall cabinets no deeper than 13 33 0 cm...

Страница 8: ...ssachusetts A T handle type manual gas valve must be installed in gas supply line to the appliance Pressure regulator All heavy duty commercial type cooking equipment must have a pressure regulator on...

Страница 9: ...rought from an intake pipe not supplied at the rear of the unit to the pressure regulator then to the manifold pipe for distribution The only connection necessary is from the service supply through th...

Страница 10: ...ter on all four sides of cooktop DGSU Bracket Installation VGSU Bracket Installation 18 2 2 2 2 1 1 1 2 Optional Gasket Remove the grates and burner caps Turn the cooktop upside down and place on a no...

Страница 11: ...h the unit for future reference 21 New units are cleaned at the factory to remove any visible signs of dirt oil grease etc remaining from the manufacturing process Some stainless steel parts may have...

Страница 12: ...23 22...

Отзывы: