45
TEMPERATURE PROBLEMS
NOTE:
Freezer temperatures above normal, 0º ± 2º F (-18º ± 1º C) will slow down the
rate of ice production. Increase ice production by setting freezer to colder setting.
1.
The freezer temperature must be below 15º F ± 3º F. Otherwise the thermostat will
not close, even if ice has formed in the mold. Here’s a quick check: Manually start
a test cycle (see above). If the temperature is above 15º F ± 3º F, the icemaker will
only complete one revolution instead of the normal two. If there is ice in the mold,
it will only complete half a revolution and then stall out against the ice.
2.
Freezer too warm. Check temperature in freezer. If temperature is appropriate for
setting, go to a lower setting (levels 5 through 9).
3.
Freezer too warm for setting. Service refrigerator.
4.
Poor airflow around icemaker. Remove obstructions.
TOO MUCH ICE
1.
Shut-off arm or internal linkage is bent or broken. Repair arm if possible, otherwise
replace icemaker.
2.
Shut-off switch not working. To test, raise shut-off arm to the OFF (up) position.
Start a test cycle. The ejector should stop after one revolution when it reaches the
park position. If ejector continues to rotate, the icemaker is faulty. Replace the
icemaker.
Содержание Designer DDFB304
Страница 1: ...F90612...
Страница 2: ...F90612 VIKING RANGE CORPORATION P O DRAWER 956 GREENWOOD MS 38930 USA...
Страница 22: ...21 Wiring Schematic 30 W All Freezer...
Страница 23: ...22 AF 30 LIGHT CIRCUITS...
Страница 24: ...23 AF 30 120V CIRCUIT...
Страница 25: ...24 AF 30 SEALED SYSTEM...
Страница 26: ...25 AF 30 ICEMAKER CIRCUIT...
Страница 27: ...26 Wiring Schematic 36 W All Freezer...
Страница 28: ...27 AF 36 LIGHT CIRCUITS...
Страница 29: ...28 AF 36 120V CIRCUIT...
Страница 30: ...29 AF 36 SEALED SYSTEM...
Страница 31: ...30 AF 36 ICEMAKER CIRCUIT...
Страница 32: ...31 Wiring Schematic 30 W All Refrigerator...
Страница 33: ...32 AR 30 120V INPUT AR 30 LIGHT CIRCUITS...
Страница 34: ...33 AR 30 SEALED SYSTEM...
Страница 35: ...34 Wiring Schematic 36 W All Refrigerator...
Страница 36: ...35 AR 36 120V INPUT AR 36 LIGHT CIRCUITS...
Страница 37: ...36 AR 36 SEALED SYSTEM...
Страница 39: ...38 ALL MODELS New Control Boards with adapter functionality...
Страница 40: ...39...
Страница 48: ...47 SEALED SYSTEM...