background image

14

13

Electric All Induction 36” Wide

Rangetop Wiring Diagram

POWER BOARD

JOUT1

JOUT2

SMALL COIL

J3

TEMP CONTROL

J14

J15

J11

J10

LED

BOARD

FRONT

REAR

LARGE COIL

JOUT3

JOUT4

J2

J12

J13

TEMP CONTROL

WHITE

YELLOW

RED

BLACK

AC

FAN

J16

J17

J6

J7

J4

J5

J18

J19

JE5

JE6

JE4

JE3

JE8

JE7

JE1

JE2

EMI BOARD

POWER BOARD

JOUT1

JOUT2

SMALL COIL

J3

TEMP CONTROL

J14

J15

SMALL COIL

POTENTIOMETER

LED

BOARD

FRONT

REAR

LARGE COIL

LARGE COIL

POTENTIOMETER

JOUT3

JOUT4

J2

J12

J13

TEMP CONTROL

RED

BLACK

WHITE

YELLOW

AC

FAN

J16

J17

J6

J7

J4

J5

J18

J19

JE5

JE6

JE4

JE3

JE8

JE7

JE1

JE2

EMI BOARD

RIGHT

CENTER

BLUE

WHITE

ORG

BROWN

SMALL COIL

POTENTIOMETER

LARGE COIL

POTENTIOMETER

SECTION

J9

J8

J9

J8

J11

J10

RED

RED

VIO

BLACK

BLACK

GRAY

RED

BLACK

BLACK

RED

VIO

GRAY

POWER LINE

CONDITIONER

J1

L1C

L2R

L2

L1

RED

BLACK

GREEN

CHASSIS GROUND

J2

L1R

L2C

J4

J3

J6

J5

L1L

L2L

POWER BOARD

JOUT1

JOUT2

SMALL COIL

J3

TEMP CONTROL

J14

J15

J11

J10

LED

BOARD

FRONT

REAR

LARGE COIL

JOUT3

JOUT4

J2

J12

J13

TEMP CONTROL

WHITE

YELLOW

RED

BLACK

AC

FAN

J16

J17

J6

J7

J4

J5

J18

J19

JE5

JE6

JE4

JE3

JE8

JE7

JE1

JE2

EMI BOARD

LEFT

SMALL COIL

POTENTIOMETER

LARGE COIL

POTENTIOMETER

J9

J8

RED

BLACK

BLACK

RED

VIO

GRAY

SECTION

SECTION

YELLOW

WHT/RED

(FRONT)

(REAR)

(REAR)

(FRONT)

(FRONT)

(REAR)

C A U T I O N

Label  all  wires  prior  to  disconnection  when
servicing  controls.  Wiring  errors  can  cause
improper  and  dangerous  operation.  Verify
proper operation after servicing.

W A R N I N G

This  unit  must  be  properly  grounded.  See
installation instructions for proper grounding
instructions. 

NOTE:

Trailers or stripes will be

the second color in a color combination.

All manuals and user guides at all-guides.com

Содержание DERT300-4B

Страница 1: ...ge Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20115A PS032607JJ All...

Страница 2: ...E MUST BE PROPERLY GROUNDED W A R N I N G The use of cabinets for storage above the appliance may result in potential fire or burn hazard Combustible items may ignite metallic items may become hot and...

Страница 3: ...BASE HEIGHT To top of glass frame To top of island trim add 1 1 4 3 2 cm 7 7 8 20 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 23 1 2 59 7 cm Overall Depth From Rear To edge of side...

Страница 4: ...irectly adjacent to existing 36 91 4 cm high base cabinets 2 The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 4...

Страница 5: ...placement parts may be used in performing service on the appliance Do not repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referr...

Страница 6: ...P CONTROL J14 J15 J11 J10 LED BOARD FRONT REAR LARGE COIL JOUT3 JOUT4 J2 J12 J13 TEMP CONTROL RED BLACK RED BLACK AC FAN J16 J17 J6 J7 J4 J5 J18 J19 JE5 JE6 JE4 JE3 JE8 JE7 JE1 JE2 EMI BOARD RIGHT SMA...

Страница 7: ...ETER LARGE COIL POTENTIOMETER J9 J8 JE5 JE6 JE4 JE3 JE8 JE7 JE1 JE2 EMI BOARD RED BLACK BLACK RED VIO GRAY BLACK RED L2 L1 SURF ELEM POWER ON LIGHT BLACK RED L P 1 H1 H2 L 2 RED RED BLK RED RED BLK PU...

Страница 8: ...ACK BLACK RED VIO GRAY POWER LINE CONDITIONER J1 L1C L2R L2 L1 RED BLACK GREEN CHASSIS GROUND J2 L1R L2C J4 J3 J6 J5 L1L L2L POWER BOARD JOUT1 JOUT2 SMALL COIL J3 TEMP CONTROL J14 J15 J11 J10 LED BOAR...

Страница 9: ...ER BOARD AC FAN J16 J17 J6 J7 J4 J5 J18 J19 POWER LINE CONDITIONER J1 L1C L2R GREEN CHASSIS GROUND ORG BROWN J2 L1R L2C J4 J3 JOUT1 JOUT2 SMALL COIL J3 TEMP CONTROL J14 J15 J11 J10 LED BOARD FRONT REA...