background image

Interior Cabinet Clearances for proper airflow

Remove the material from this area
for proper air flow into the unit.

3” (7.6 cm)

2” 
(5.1 cm)

2 3/4” 
(7.0 cm)

8” (20.3 cm)

8” (20.3 cm)

3” (7.6 cm)

1 1/2” 
(3.8 cm)

1 1/2” dia.
cutout for
conduit

IIM

MP

PO

OR

RT

TA

AN

NT

T::

The electronic components for the

induction elements in the rangetop need some air
circulation.  To  ensure  long  life  of  electronic
components,  it  is  required  that  a  minimum  of  8”
(20.3  cm)  of  open  space  remain  between  the
bottom  of  the  unit  and  any  shelf  underneath.  The
maximum  length  of  the  shelf  underneath  is  to  be
18” (45.7 cm)  There should be no partition or shelf
d

diirre

eccttllyy underneath the unit.

8” Min.

(20.3 cm)

18” Max.
(45.7 cm)

6

Proximity to cabinet installation

1.  This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.  

2.  The  rangetop  CANNOT be  installed  directly  adjacent  to  sidewalls,  tall  cabinets,  tall

appliances,  or  other  side  vertical  surfaces  above  36”  (91.4  cm)  high.    There  must  be  a
minimum  of  6”  (15.2  cm)  side  clearance  from  the  rangetop  to  such  combustible  surfaces
above the 36” (91.4 cm) counter height.

3.  Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm),

the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2
cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop. 

4.  Wall cabinets above the rangetop must be a minimum of 36” (91.4 cm) above the rangetop

cooking surface for the full width of the rangetop.

13” Max

(33.0 cm)

36” Min.
(91.4 cm)

7 1/2”
(19.1 cm)

18” Min.

(45.7 cm)

6” Min.

(15.2 cm)

36” Min.

(91.4 cm)

S

SIID

DE

E

F

FR

RO

ON

NT

T

5

Installation

Clearances

Detailed View of Bottom Support

All manuals and user guides at all-guides.com

Содержание DERT300-4B

Страница 1: ...ge Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20115A PS032607JJ All...

Страница 2: ...E MUST BE PROPERLY GROUNDED W A R N I N G The use of cabinets for storage above the appliance may result in potential fire or burn hazard Combustible items may ignite metallic items may become hot and...

Страница 3: ...BASE HEIGHT To top of glass frame To top of island trim add 1 1 4 3 2 cm 7 7 8 20 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 23 1 2 59 7 cm Overall Depth From Rear To edge of side...

Страница 4: ...irectly adjacent to existing 36 91 4 cm high base cabinets 2 The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 4...

Страница 5: ...placement parts may be used in performing service on the appliance Do not repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referr...

Страница 6: ...P CONTROL J14 J15 J11 J10 LED BOARD FRONT REAR LARGE COIL JOUT3 JOUT4 J2 J12 J13 TEMP CONTROL RED BLACK RED BLACK AC FAN J16 J17 J6 J7 J4 J5 J18 J19 JE5 JE6 JE4 JE3 JE8 JE7 JE1 JE2 EMI BOARD RIGHT SMA...

Страница 7: ...ETER LARGE COIL POTENTIOMETER J9 J8 JE5 JE6 JE4 JE3 JE8 JE7 JE1 JE2 EMI BOARD RED BLACK BLACK RED VIO GRAY BLACK RED L2 L1 SURF ELEM POWER ON LIGHT BLACK RED L P 1 H1 H2 L 2 RED RED BLK RED RED BLK PU...

Страница 8: ...ACK BLACK RED VIO GRAY POWER LINE CONDITIONER J1 L1C L2R L2 L1 RED BLACK GREEN CHASSIS GROUND J2 L1R L2C J4 J3 J6 J5 L1L L2L POWER BOARD JOUT1 JOUT2 SMALL COIL J3 TEMP CONTROL J14 J15 J11 J10 LED BOAR...

Страница 9: ...ER BOARD AC FAN J16 J17 J6 J7 J4 J5 J18 J19 POWER LINE CONDITIONER J1 L1C L2R GREEN CHASSIS GROUND ORG BROWN J2 L1R L2C J4 J3 JOUT1 JOUT2 SMALL COIL J3 TEMP CONTROL J14 J15 J11 J10 LED BOARD FRONT REA...

Отзывы: