Component Testing–Control Board
Component
Board
Test Point
Reading
Condenser Motor
Control
J1-1 (Blue) to J1-8 (White)
4.7
1
Defrost Terminator
Control
J1-2 (Brown) to J2-5 (Orange)
'
Open 0
1
Closed
*Depends on coil temperature
Evaporator Fan Motor
(120 volt)
Control
J1-3 (Black) to J1-8 (white)
1637
1
Evaporator Fan
Control
J6-5 (Black/Yellow) to J6-1 (Black/Green)
6.54K
1
Damper
Control
J1-4 (Red) to J1-7 (Yellow/Red)
2.4K
1
Damper Switch
Control
J1-4 (Red) to J2-4 (Blue/Red)
0
1
switch closed
'1
switch open
Refrigerator Lights
Control
J1-6 (Red/White) neutral to J1-4 (Red) Line
Conditions: Either fresh food door must be
open and power disconnected.
8.8
1
Refrigerator Light Switch
(N.C.)
Control
J2-1 (Tan/Red) to J1-4 (red).
Conditions: Either fresh food door must be
open and power disconnected
0
1
door open
'1
door closed
Refrigerator Interlock Switch
(N.O.)
Control
J2-10 (Black/Red) to J1-4 (Red)
0
1
door closed
'
door open
Freezer Light Switch
Control
J1-4 (Red) to J2-6 (Gray/White).
0
1
door closed
'
door open
Freezer Lights
Control
J1-6 (Red/White) to J2-6 (Gray/White)
25.1
1
Ice Maker Switch
Control
J2-8 Violet) to J2-2 (Gray)
0
1
switch on
'1
switch off
Ice Maker
Control
J2-8 (Yellow) to J1-8 (White)
266
1
Ice Auger
Control
J2-9 (Pink) to J1-8 (White)
4.4
1
Icemaker Thermistor
Control
J3-4 (White/Black) to J3-5 (White/Orange)
9.31K
1
@ room temperature
Freezer Thermistor
Control
J3-2 (White/Yellow) to J3-5 (White/Orange)
9.38K
1
Refrigerator Thermistor
Control
J3-1 (White/Blue) to J3-5 (White/Orange)
7.63K
1
Ice Fan
Control
J6-2 (Red/Black) to J6-4(Blue/Black)
26.8K
1
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. After servicing, reconnect power using power switch.