CLEANING STEP
Inlet valve
140 pulse*
0.2 gal
Circulation pump
20 sec
Low pressure lower arm
Outlet Pump
25 sec
FIRST RINSE
Inlet valve`
540 pulse*
0.7 gal
Circulation pump
240 sec
Circulation pump
60 sec
High pressure upper arm
Outlet pump
2 sec
SCS stage
Circulation pump
20 sec
SCS stage
Outlet pump
25 sec
LAST RINSE
Inlet valve
540 pulse*
0.7 gal
Circulation pump
60 sec
Circulation pump, element
122º F
Circulation pump, dispenser
60 sec
Circulation pump
240 sec
Circulation pump
50 sec
High pressure upper arm
Pause
60 sec
Drip off
Outlet pump
25 sec
85 seconds between Circulation pump and fan start
DRYING
Fan
1200
sec
* Pulse = number of pulses from the flow sensor to obtain the given quantity of water
** Applicable to a machine with spray arm dividers. 1 stage (with an additional
circulation pump) where not spray arm divider status is indicated, sequential 30
seconds lower arm low pressure, 30 seconds lower arm high pressure, 30 seconds
upper arm low pressure, 30 seconds upper arm high pressure are intended.
16
Содержание Custom Front DFUD042
Страница 1: ......
Страница 2: ...VIKING RANGE CORPORATION P O DRAWER 956 GREENWOOD MS 38930 USA...
Страница 5: ...CONTROL PANELS DISHWASHER FEATURES 4...
Страница 15: ...THE INDICATING LAMPS DFUD140 14...
Страница 29: ...28...
Страница 31: ...30...
Страница 32: ...31...
Страница 33: ...32...