DFUD040/140
Illustrated below is a normal program and the sequence in which the various
components are connected.
NORMAL WASH
Component Comments
Outlet pump
25 seconds
RINSE/HOLD
Inlet valve
540 pulse*
0.7 gal
Circulation pump
30 sec
High pressure upper arm**
Pause
1
sec
Circulation pump
240 sec
High pressure lower arm**
Circulation pump
60 sec
High pressure upper arm**
Circulation pump
240 sec
High pressure lower arm
Circulation pump
60 sec
High pressure upper arm
Outlet pump
2 sec
SCS stage
Circulation pump
20 sec
SCS stage, High pressure
upper
arm
Outlet pump
25 sec
CLEANING STEP
Inlet valve
300 pulse*
0.4 gal
Circulation pump
30 sec
High pressure upper arm
Pause
5
sec
Circulation pump
5 sec
High pressure upper arm
Pause
5
sec
Circulation pump
5 sec
High pressure upper arm
Outlet pump
25 sec
MAIN WASH
Inlet valve
540 pulse*
0.7 gal
Circulation pump
60 sec
High pressure upper arm
Circulation pump, dispenser
3 sec
High pressure upper arm
Circulation pump, element
90º F
Enzym step
Circulation pump
180 sec
Circulation pump, element
130º F
Circulation pump
600 sec
Circulation pump
60 sec
High pressure upper arm
Outlet pump
2 sec
SCS stage
Circulation pump
20 sec
SCS stage, high pressure
upper
arm
Outlet pump
25 sec
15
Содержание Custom Front DFUD042
Страница 1: ......
Страница 2: ...VIKING RANGE CORPORATION P O DRAWER 956 GREENWOOD MS 38930 USA...
Страница 5: ...CONTROL PANELS DISHWASHER FEATURES 4...
Страница 15: ...THE INDICATING LAMPS DFUD140 14...
Страница 29: ...28...
Страница 31: ...30...
Страница 32: ...31...
Страница 33: ...32...