Triggers:
Clicking the “Triggers”
button in the “Event Programming”
section will open the “Triggers”
programming screen where you can
enter/program the parameters for
Trigger Inputs 1-4 such as which
wave file to play, Contact
(N.O./N.C.), Trigger Mode (Alt
Action/Activate Only), Play Count (1-
99 or Continuous), Volume setting,
Type (Mom / Cont) and Playback
Mode (Interrupt/stack).
Note:
The
CTG-2A
is factory loaded
with the following wave files for
Trigger Inputs 1-4:
Trigger 1:
Evac Signal.wav (ANSI
S3.41/ISO 8201 Audible Emergency
Evacuation Signal)
Trigger 2:
All Clear 3 sec.wav
Trigger 3:
Attack Wail.wav
Trigger 4:
CTG-1 Siren 5sec.wav
Troubleshooting Communication Errors
1.
If you open the PC software with a
CTG-2A
connected, occasionally a communications error will occur
between the PC and the
CTG-2A
and a message will pop up saying the
CTG-2A
is missing some of its wave
files, when they are not missing. If you get this type of error message, close the software and re-open it.
2.
A similar miscommunication can cause the Login prompt to appear repeatedly, if this happens, close the
software and re-open it. If you are again prompted for the login, you can reset the
CTG-2A
’s login and network
settings by turning DIP switch 2 to ON for 5 seconds (see page 18).
3.
If the
CTG-2A
displays “Pro” when the PC software is not open, momentarily power down the
CTG-2A
and
the display should clear.
4.
If you open the PC software and a message says: “error on directory position 15”, close the PC software and
power down the
CTG-2A
. Reconnect power and open the PC software again.
5.
Firewall issues: The following ports are used by the
CTG-2A
and must not be blocked or firewalled for it to
function: TCP 80*, TCP 9761*, UDP123*, UDP 6234 and UDP 30303. *Can be changed in software.