background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

DOD# 653

ZF301700 Rev D

Printed in the U.S.A.

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

When the 

LDB-3

control module detects an incoming ring signal, it activates a set of normally open or normally closed contacts and

turns on the 12VDC output for activating the provided strobe light.  With the Ring Cadence mode off (DIP switch 2 OFF), the relay
will activate and the strobe light will flash only during ringing.  With the Ring Cadence mode ON (DIP switch 2 ON), the relay will
remain activated and the strobe light will remain flashing between rings.

A. Ring Indication

(DIP Switch 1 ON)

When the 

LDB-3

control module detects an off-hook condition (loop current) on the brown and gray wires, it activates a set of nor-

mally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light.  The relay contacts
will remain activated and the blue strobe light will flash during the off-hook condition and will stop flashing approximately 3 seconds
after the phone/terminal device on the brown and gray wires is back on-hook.

B. Off-Hook Indication

(DIP Switch 3 ON)

O

O

t

t

h

h

e

e

r

r

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

A. Mounting the BLK-3-EWP with the E-1600-20A

1/2" Liquid Tight 

Conduit Connector

1/2" PVC Conduit 

Straps

1/2" Liquid Tight 

Conduit

1/2" Liquid Tight 

Conduit Connector

Step 1.   

Drill or use a knockout punch to provide a .875” diameter hole in the top of the 

VE-5x5

.

Step 2.

Make all conduit connections.

Step 3.

Make all wire connections to the 

LDB-3

control module.

Step 4.

Install the 

E-1600-20A

as explained in its Technical Practice, 

DOD# 215

.

The 

BLK-3-EWP

can be used in conjunction with the 

E-1600-20A

Two-Button Emergency Phone as

shown to the far right, however, special installation and mounting is required.  Please follow the steps
below when using the 

BLK-3-EWP

in conjunction with a surface-mounted 

E-1600-20A

.  A 

VE-5x5

sur-

face-mount box is required, see 

DOD# 424

.

E-1600-20A
and VE-5x5

(not included)

F. Disable Feature

By connecting the Disable/Info Switch input of the 

LDB-3

control module to

the “

Info

” switch of Viking’s 

E-1600-20A

E-1600-20A-EWP

E-1600-52A

or

E-1600-52A-EWP

Emergency Phone, any outbound call initiated from the

Info

” button will not activate the strobe light.  This way, only the

Help/Emergency

” outbound calls will activate the relay.  Cut one of the “

Info

switch wires in half and connect each end to the blue wires on the 

LDB-3

con-

trol module as shown in the diagram at the right.  

Note: 

This Disable input is

NOT

polarity sensitive.  

The “

Disable

” input can be connected to a switch for

remotely disabling/turning off the device (strobe light, camera, etc.) controlled
by the 

LDB-3

. For more information, see 

DOD# 866

.

1

2

O

N

3

1

2

3

4

5

6

7

8

9

10

11

V

IK

IN

G

Model: 

xxxxxxx

Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016

S/N: 

XXXXXX

P/N: 

xxxxxxx

Rear View of E-1600-20A

LDB-3

Control Module

Blue

Blue

Gel-Filled Butt

Connectors (included)

D. Relay Contacts

Normally open and normally closed relay contacts are available on the orange, purple and yellow wires. The contacts are rated at .5A @
125VAC/1A @ 30VDC.  If contacts are driving an inductive load, place a suppression device at the load to snub high voltage spikes. 

E. Switched 12V DC Output

The switched 12V DC output is a low current, 12-15VDC output that is turned on only while the ring/loop detect relay is activated.
This switched power output is ideal for lighting the included strobe light or providing 12-15V DC power to any device that draws less
than 350mAmps.  The positive side is available on the red wire, and the negative side is on the black wire. Once all the line and
load connections have been made, plug in the 115 V AC wall adapter, and replace the cover.

B. Operating a BLK-3-EWP with a Contact Closure

390 Ohm - 750 Ohm, 1/2 Watt Resistor

(Radio Shack part # 271-1114, 271-1115, 

271-1116, 271-1117 or equivalent)

1      2       3      4      5      6       7      8      9     10     11

Z3

Z3

Z2

Z2

R

5

R

2

R4

R4
R7

R7
R9

R9
R8

R8

CR

CR

2

Wire Nuts

(not included)

Black with

White stripe

120V AC

      Red with

Black stripe

Black

Black with 

White stripe

Brown

Gray

Green with 

Yellow stripe

     Red with

Yellow stripe

Содержание BLK-3-EWP

Страница 1: ...59 The kit includes 1 LDB 3 control module 1 blue strobe light 1 12V DC power adapter 13 gel filled butt con nectors and 1 single gang weatherproof mounting box with gaskets and hardware LDB 3 control module comes with Enhanced Weather Protection EWP EWP products are designed to meet IP66 Ingress Protection Rating see DOD 859 Durable polycarbonate lens Long life 1 million candle power blue strobe ...

Страница 2: ... 715 386 8666 to determine possible causes for the problem The customer MUST be able to step through recommended tests for diagnosis 2 If the Technical Support Product Specialist determines that the equipment is defective based on the customer s input and troubleshooting a Return Authorization R A number will be issued This number is valid for fourteen 14 calendar days from the date of issue 3 Aft...

Страница 3: ... line and the phone terminal device to be monitored Connect the incoming line to the red and green wires with the yellow stripe con nect the phone terminal device to the brown and gray wires 1 Ring Indication Only Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram No phone terminal device is required The LDB 3 control module can monitor for ringing ...

Страница 4: ...steps below when using the BLK 3 EWP in conjunction with a surface mounted E 1600 20A A VE 5x5 sur face mount box is required see DOD 424 E 1600 20A and VE 5x5 not included F Disable Feature By connecting the Disable Info Switch input of the LDB 3 control module to the Info switch of Viking s E 1600 20A E 1600 20A EWP E 1600 52A or E 1600 52A EWP Emergency Phone any outbound call initiated from th...

Отзывы: