background image

29

2

1

HI/L

ITE

4

1/2

"

(1.3

 cm

)

3/8

"

(.95

 cm

)

CORRECT

YELLOW

BLUE LIFTING

5

Push and turn the the valve to light the burner and

adjust according to the directions following. 

NOTE:

By

replacing the knob, it may be easier to light the burner.

1

Off

6

2

3

7

Once adjusted, turn the burner off, tighten the set

screw on the air shutter. For grill burners, replace the

valve panel and knobs.

Replace the drip tray.

3

3

1

Off

2

Once adjusted, turn the burner off, tighten the set screw

on the air shutter. For side burners, replace the grate

support, burner bowls, and grates for the side burners.

If the flame is yellow, turn the air shutter counter

clockwise to allow more air to the burner. If the flame is

noisy and lifting away from the burner, turn the air shutter

clockwise to reduce the amount of air to the burner.

28

1

2

To access the air shutter on the grill burners, remove

the drip tray.

Remove the knobs and valve panel. 

NOTE:

Leave wires

connected to switches on valve panel.

3

To access the air shutter on the side burners, remove

the grates, burner bowls, and grate support.

With a screw driver, loosen the lock-screw on the face

of the air shutter.

Burner Adjustment

Each  burner  is  tested  and  adjusted  at  the
factory prior to shipment; however, variations
in the local gas supply may make it necessary
to  adjust  the  burners.  The  flames  of  the
burners (except the rotisserie infrared burner)
should  be  visually  checked  and  compared
with the following illustrations.

Flames  should  be  blue  and  stable  with  no
yellow tips, excessive noise or lifting. If any of
these conditions exist, check if the air shutter
or  burner  ports  are  blocked  by  dirt,  debris,
spider webs, etc. With a proper flame height,
adjust  the  air  shutter  to  obtain  a  blue  flame
with no yellow tipping that sits on the burner
at the burner ports. The air shutter is locked
in  place  by  a  set  screw  which  must  be
loosened  prior  to  lighting  the  burner  for
adjustments.

CORRECT

YELLOW

BLUE LIFTING

Содержание 30inch 500 VGBQ

Страница 1: ... 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20456H EN 050311 Viking Installation Guide Outdoor Gas Grills ...

Страница 2: ...arm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed in the flame during combustion However exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame minimize incomplete combustion Before beginning plea...

Страница 3: ... Propane Equipped with high capacity hose regulator assembly for connection to standard 5gal 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 9 volt DC battery for electronic ignition 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor except 030 Grill burner ra...

Страница 4: ...pane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 9 volt DC battery for electronic ignition 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 25 000 BTU Nat 22 500 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW ...

Страница 5: ...0VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW Nat LP 30 000 BTU Nat LP 8 3 kW Nat LP Side burner rating If applicable N A N A ...

Страница 6: ...1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW Nat LP Side burner rating I...

Страница 7: ...neath the solid bottom support at a maximum distance of 2 feet This connection is to be used for the ignition system and canopy lights In addition the rotisserie motor requires a separate 110 120 volt supply to be located on the right hand side of the grill Both the power supply cords for the ignition lights and the rotisserie motor are equipped with a 3 prong grounded plug for protection against ...

Страница 8: ... cm to combustable surface 6 15 2 cm 14 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 41 3 16 104 6 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface 6 15 2 cm Clearance Dimensions 41 Grill 15 Clearance Dimensions 30 Grill VGBQ300T2 VGBQ300E2 VGIQ410T2 VGBQ410E2 VGBQ412E2 VGIQ410E2 ...

Страница 9: ...l This allows grill CP to sit back properly in the cutout Gas inlet and power cord location area 5 1 2 7 c m 5 1 2 7 c m 1 2 1 2 cm 1 2 1 2 cm Cutout Dimensions 30 Grill 17 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 6 15 2 cm 41 3 16 104 6 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface Clearance Dimensions...

Страница 10: ... Electrical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on E Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Gas inlet and power cord location area 5 12 7 cm 5 12 7 cm Countertop typically requires 1 2 wide by 1 2 deep notch cut...

Страница 11: ...r cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug This unit is not fused and installer must install a GFI Unit must be grounded in accordance with local codes or with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 Ventil...

Страница 12: ...ired Male Male coupler coupler Male coupler Installer supplied flexible gas line with 1 2 female adapter or Viking GHS12 Installer supplied shut off valve must be easily accessible female coupler 7 8 male flare adapter Regulator assembly Natural Fixed Piping Connection 22 Check with your local gas utility company or with local codes for instructions on installing gas supply lines Be sure to check ...

Страница 13: ...rchased after October 1 1998 and will ensure that the tank is not overfilled The LP Propane tank should be a standard 5 gal 20 lb gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP Propane Gas Cylinders of the U S Department of Transportation D O T or the National Standard of Canada CAN CSA B339 Cylinders Sph...

Страница 14: ...he OFF position 3 4 Apply the soap solution to fittings Turn cylinder valve knob counter clockwise one turn to open Leak Testing Although all gas connections on the grill are leak tested at the factory prior to shipment a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit Periodicall...

Страница 15: ...ip tray Remove the knobs and valve panel NOTE Leave wires connected to switches on valve panel 3 To access the air shutter on the side burners remove the grates burner bowls and grate support With a screw driver loosen the lock screw on the face of the air shutter Burner Adjustment Each burner is tested and adjusted at the factory prior to shipment however variations in the local gas supply may ma...

Страница 16: ...tained to combustible materials Pressure regulator connected and set Manual shut off valve installed and accessible Check air shutter adjustment sharp blue flame no yellow tipping Check for gas leaks odors at all gas connections Each burner lights satisfactorily individually or with adjacent burners lit Any adjustments necessary that are the result of the installer not following instructions will ...

Страница 17: ...model number for your appliance are located on the identification plate mounted on the bottom left side of the door opening Model number ___________________________________________________________ Serial number ___________________________________________________________ Date of purchase ___________________________________________________________ Date installed _____________________________________...

Страница 18: ...35 34 ...

Отзывы: