background image

Gas and Electrical Connection

GAS  CONNECTION

Verify the type of gas supply to be used,
either natural or LP, and make sure the
marking on the grill rating plate agrees with
that of the supply. Never connect an
unregulated gas line to the appliance. An
installer supplied gas shut-off valve must be
installed in an easily accessible location. All
installer supplied parts must conform to local
codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70
and the National Fuel Code, ANSI
Z223.1/NFPA 54. 

In Canada: 

Installation must be in

accordance with the current CSA-B149.1,
Natural Gas Installation Code or CSA-
B149.2, Propane Installation Code and/or
local codes. All pipe sealants must be an
approved type and resistant to the actions of
LP gas. Never use pipe sealant on flare
fittings. All gas connections should be made
by a competent technician and in
accordance with local codes and or
ordinances. In the absence of codes, the
installation must comply with the National
Fuel Gas Code ANSI Z223.1/NFPA 54. The
gas grill and its individual shut-off valve must
be disconnected from the gas supply piping
system during any pressure testing of that
system at test pressures in excess of 1/2
PSIG (3.5 kPa). The gas grill must be isolated
from the gas supply piping system by
closing its individual manual shut-off valve
during any pressure testing of that system at
test pressures equal to or less than 1/2 psi
(3.5 kPa). Built-in installations must be
plumbed using a fixed/hard line if the unit is
going to be operated at a distance
exceeding 3 feet (0.91 meters) from the fuel
supply per ANSI Z21.24 CSA.

GAS  CONVERSION 

To  convert  a  grill  from  natural  to
LP/Propane  or  LP/Propane  to  natural,  you
MUST use conversion kit sold seperately.

ELECTRICAL CONNECTION

21

WARNING

DANGER

CAUTION

FOR YOUR SAFETY

Conversions should only be performed by an
authorized service technician.

WARNING

ELECTRICAL SHOCK HAZARD

This  appliance  is  equipped  with  a  3’
(91.4 cm) 3-prong power cord with a
grounding  plug  for  your  protection
against  shock  hazard  and  should  be

plugged  directly  into  a  properly  grounded
receptacle. Do not cut or remove the grounding
prong  from  this  plug.  This  unit  is  not  fused  and
installer  must  install  a  GFI.  Unit  must  be
grounded in accordance with local codes or with
the  National  Electrical  Code  ANSI/NFPA  70,  or
the Canadian Electrical Code, CSA C22.1.

Ventilation for Built-In Installations When
Using an Enclosed LP-Gas Cylinder

20

Vents

1.00 inch maximum

5.00 inch
maximum

All vents no more than 5.00 inches
above the floor of the installation.

5.00 inch
maximum

Not more than 5.00 
inches from inside
bottom of countertop.

Bottom Vent not
more than 1.00 inch 
from inside floor of 
installation.

An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower
levels  of  the  enclosure.  The  effectiveness of  the opening(s)  for  purposes  of  ventilation  shall be
determined with the LP-gas supply cylinder in place. This shall be accompanied by one of the
following:

a.

One side of the enclosure shall be completely open; or

b. For an enclosure having four sides, a top and a bottom:

1. At least two ventilation openings (See Part IV, Definitions) shall be provided in the side 

walls of the enclosure, located within 5 in. (217 mm) of the top of the enclosure, equally
sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s)
shall have a total free area of not less than 1 in

2

/lb (1.42 cm

2

/kg) of stored fuel capacity.

2. Ventilation opening(s) shall be provided at floor level at rear of the enclosure and shall

have a total free area of not less than 1/2 in

2

/lb (7.1 cm

2

/kg) of stored fuel capacity. The

bottom of the openings shall be 1 in. (25.4 mm) or less from the floor level and the
upper edge no more than 5 in. (127 mm) above the floor level. The openings shall be
equally sized, spaced at a minimum of 90 degrees (1.57 rad) and unobstructed.

3. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch

(3.2 mm) diameter rod.

4. Ventilation openings in the side walls shall not communicate directly with other

enclosures of the outdoor cooking gas appliance.

Vents located
on sidewall

Содержание 30inch 500 VGBQ

Страница 1: ... 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20456H EN 050311 Viking Installation Guide Outdoor Gas Grills ...

Страница 2: ...arm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed in the flame during combustion However exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame minimize incomplete combustion Before beginning plea...

Страница 3: ... Propane Equipped with high capacity hose regulator assembly for connection to standard 5gal 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 9 volt DC battery for electronic ignition 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor except 030 Grill burner ra...

Страница 4: ...pane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 9 volt DC battery for electronic ignition 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 25 000 BTU Nat 22 500 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW ...

Страница 5: ...0VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW Nat LP 30 000 BTU Nat LP 8 3 kW Nat LP Side burner rating If applicable N A N A ...

Страница 6: ...1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor Grill burner rating 29 000 BTU Nat 28 000 BTU LP 7 3 kW Nat 6 5 kW LP TruSear burner rating If applicable 30 000 BTU Nat LP 8 3 kW Nat LP Side burner rating I...

Страница 7: ...neath the solid bottom support at a maximum distance of 2 feet This connection is to be used for the ignition system and canopy lights In addition the rotisserie motor requires a separate 110 120 volt supply to be located on the right hand side of the grill Both the power supply cords for the ignition lights and the rotisserie motor are equipped with a 3 prong grounded plug for protection against ...

Страница 8: ... cm to combustable surface 6 15 2 cm 14 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 41 3 16 104 6 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface 6 15 2 cm Clearance Dimensions 41 Grill 15 Clearance Dimensions 30 Grill VGBQ300T2 VGBQ300E2 VGIQ410T2 VGBQ410E2 VGBQ412E2 VGIQ410E2 ...

Страница 9: ...l This allows grill CP to sit back properly in the cutout Gas inlet and power cord location area 5 1 2 7 c m 5 1 2 7 c m 1 2 1 2 cm 1 2 1 2 cm Cutout Dimensions 30 Grill 17 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 6 15 2 cm 41 3 16 104 6 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to non combustable surface 24 min 61 0 cm to combustable surface Clearance Dimensions...

Страница 10: ... Electrical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on E Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Gas inlet and power cord location area 5 12 7 cm 5 12 7 cm Countertop typically requires 1 2 wide by 1 2 deep notch cut...

Страница 11: ...r cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug This unit is not fused and installer must install a GFI Unit must be grounded in accordance with local codes or with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 Ventil...

Страница 12: ...ired Male Male coupler coupler Male coupler Installer supplied flexible gas line with 1 2 female adapter or Viking GHS12 Installer supplied shut off valve must be easily accessible female coupler 7 8 male flare adapter Regulator assembly Natural Fixed Piping Connection 22 Check with your local gas utility company or with local codes for instructions on installing gas supply lines Be sure to check ...

Страница 13: ...rchased after October 1 1998 and will ensure that the tank is not overfilled The LP Propane tank should be a standard 5 gal 20 lb gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP Propane Gas Cylinders of the U S Department of Transportation D O T or the National Standard of Canada CAN CSA B339 Cylinders Sph...

Страница 14: ...he OFF position 3 4 Apply the soap solution to fittings Turn cylinder valve knob counter clockwise one turn to open Leak Testing Although all gas connections on the grill are leak tested at the factory prior to shipment a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit Periodicall...

Страница 15: ...ip tray Remove the knobs and valve panel NOTE Leave wires connected to switches on valve panel 3 To access the air shutter on the side burners remove the grates burner bowls and grate support With a screw driver loosen the lock screw on the face of the air shutter Burner Adjustment Each burner is tested and adjusted at the factory prior to shipment however variations in the local gas supply may ma...

Страница 16: ...tained to combustible materials Pressure regulator connected and set Manual shut off valve installed and accessible Check air shutter adjustment sharp blue flame no yellow tipping Check for gas leaks odors at all gas connections Each burner lights satisfactorily individually or with adjacent burners lit Any adjustments necessary that are the result of the installer not following instructions will ...

Страница 17: ...model number for your appliance are located on the identification plate mounted on the bottom left side of the door opening Model number ___________________________________________________________ Serial number ___________________________________________________________ Date of purchase ___________________________________________________________ Date installed _____________________________________...

Страница 18: ...35 34 ...

Отзывы: