Manual
11/29/2018
PSFEM6xxxxZxxx
Viking Technology
Revision G
Page 37 of 41
www.vikingtechnology.com
SMART
Attribute ID
Description
B1h
Wear Range delta [(most wear block
– average wear block)/Max P/E
cycles] x 100
B5h
Program Fail Count
B6h
Erase Failure Block Count
BBh
Reported Uncorrectable Errors (ECC fail count) 4bytes 01h only 1 bytes
C0h
Unexpected Power Loss Count
C2h
N/A
C7h
Number of accumulated CRC Error (read/write data FIS CRC error)
CRC Error Count (R CRC + W CRC)
DAh
Number of accumulated CRC Error (read/write data FIS CRC error)
Number of CRC Errors
E7h
SSD life remaining
E8h
Read Failure Block Count
E9h
Lifetime Writes to Flash ((GB)
F1h
Lifetime Writes from Host (each G)
F2h
Lifetime Reads from Host (each G)
F3h
Total internal copy ecc error count
F4h
Average erase count (4bytes)
F5h
Max erase count (4 bytes)
F6h
Total Erase Count (6 bytes)
FAh
Read retry count
FBh
Do wearleveling count
FCh
CRC error write count
Notes:
1. Dummy is null and not used
Table 5-5: Extended SMART Attribute Actual Data
0
1
2
3
4
5
6
7
8
9
10
11
ID
Flag
Flag
Value
Worse
DATA
Threshold
01h
0Bh
00h
64h
64h
0
0
ECC error
0
0
0
0
32h
05h
13h
00h
64h
64h
0
0
0
0
0
0
0
32h
09h
12h
00h
64h
64h
Power on hour
0
0
0
0
0
00h
0Ch
12h
00h
64h
64h
Power on/off cycles
0
0
0
00h
A8h
12h
00h
64h
64h
SATA PHY error count
0
0
0
00h
AAh
03h
00h
Note
1
Note
1
Early bad block NO
0
0
Later bad block
NO
0
0Ah