background image

99044605A

F20073

PROFESSIONAL SERIES

BUILT-IN REAR DOWNDRAFT WARRANTY

ONE YEAR  FULL WARRANTY

Built-in downdraft ventilators, all of their component parts and accessories, except as detailed below*, are warranted to be free 
from defective materials or workmanship in normal household use for a period of twelve (12) months from the date of original 
retail purchase. Viking Range Corporation, warrantor, agrees to repair or replace, at its option, any part which fails or is found 
to be defective during the warranty period. For the purpose of this warranty, normal household use 

shall not 

include use of this 

downdraft ventilator with a cooking unit that has a grill. The Viking warranty does not cover any additional ventilation products not 
provided by Viking used in conjunction with Viking downdrafts or ventilator kits. This includes, but is not limited to, such devices 
as booster fans or in-line blowers. Any malfunction caused to Viking ventilation products as a direct result of the use of such 
equipment is not covered under the Viking warranty.

Painted and decorative items are warranted to free from defective materials or workmanship for a period of ninety (90) days from 
the date of original retail purchase. ANY DEFECTS MUST BE REPORTED TO THE SELLING DEALER WITHIN NINETY (90) 
DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE.

FIVE YEAR  LIMITED WARRANTY

Any ventilator motor which fails due to defective materials or workmanship in normal household use during the second through 
the fifth year from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner 
paying all other costs, including labor.

This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product 
during the term of the warranty.

This warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in 
the country where service is requested. Warranty labor shall be performed by an authorized Viking Range Corporation service 
agency or representative. Warranty shall not apply to damage resulting from abuse, accident, natural disaster, loss of electrical 
power to the product for any reason, alteration, outdoor use, improper installation, improper operation or repair or service to the 
product by anyone other than an authorized Viking Range Corporation service agency or representative. This warranty does not 
apply to commercial usage. Warrantor is not responsible for consequential or incidental damage whether arising out of breach of 
warranty, breach of contract, or otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply to you.

Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon 
request, and making the appliance reasonably accessible for service. If the product or one of its component parts contains a 
defect or malfunction during the warranty period, after a reasonable number of attempts by the warrantor to remedy the defects or 
malfunctions, the owner is entitled to either a refund or replacement of the product or its component part or parts. Replacement of 
a component part includes its free installation. Warrantor’s liability on any claim of any kind, with respect to the goods or services 
covered hereunder, shall in no case exceed the price of the goods or service or part there of which gives rise to the claim.

WARRANTY SERVICE: 

Under the terms of this warranty, service must be performed by a factory authorized Viking Range 

Corporation service agent or representative. Service will be provided during normal business hours, and labor performed at 
overtime or premium rates shall not be covered by this warranty. To obtain warranty service, contact the dealer from whom the 
product was purchased, an authorized Viking Range Corporation service agent, or Viking Range Corporation. Provide model and 
serial number and date of original purchase. For the name of your nearest authorized Viking Range Corporation service agency, 
call the dealer from whom the product was purchased or Viking Range Corporation. 

IMPORTANT: 

Retain proof of original 

purchase to establish warranty period.

The return of the Owner Registration Card is not a condition of warranty coverage. You, however, should return the Owner 
Registration Card so that Viking Range Corporation can contact you should any question of safety arise which could affect you.
Any implied warranties of merchantability and fitness applicable to the above described ventilator motor are limited in duration 
to the period of coverage of the applicable express written limited warranties set forth above. Some jurisdictions do not allow 
limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific 
rights, and you may also have other rights which may vary from jurisdiction to jurisdiction.

VIKING RANGE CORPORATION

111 Front Street

Greenwood, Mississippi  38930 USA

(662) 455-1200

Specifications subject to change without notice.

For more product information, call 1-888-VIKING1 (845-4641), or visit the Viking

web site at http://www.vikingrange.com

All manuals and user guides at all-guides.com

Содержание VIPR101RSS

Страница 1: ...lways use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWINGa 1 SMOTHERFLAMESwithaclose fittinglid cookiesheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immedi ately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You m...

Страница 2: ...nted in island peninsula orconventionalwall locations Thisunitcanbeeasilyinstalled following these basic steps Cut out the countertop opening Mount the unit in the cabinet Install 10 round dis charge plate Install Model VEDV900 or VEDV1200 48 Model ONLY External Blower Connect the ductwork and electrical Install the cooktop COOK TOP COUNTER TOP CHIMNEY TOP 10 ROUND DISCHARGE PLATE 10 ROUND DUCTWOR...

Страница 3: ... feet of transitions and or elbows to be used should equal 40 feet or less NOTE The equivalent feet of various roof and wall caps has been taken into consideration Do not include them in this calculation 3 1 4 X 10 TO 6 RD TRANSITION 3 1 4 X 10 90O ELBOW 29 5 16 2 1 8 VIDV500 INTERNAL BLOWER 5 2 1 3 1 4 3 5 8 1 4 7 11 16 18 FROM COUNTERTOP TO BOTTOM OF AIR BOX 29 5 16 2 1 8 2 1 3 1 4 3 5 8 1 4 7 1...

Страница 4: ...F COUNTER CUTOUT CENTER LINE OF DUCT CUTOUT 2 10 10 ROUND DIA CUTOUT TYP 3 6 CENTER LINE OF DUCT CUTOUT can be located within this area CENTER LINE OF COUNTER CUTOUT 19 10 10 ROUND CUTOUT TYP CENTER LINES OF DUCT CUTOUT CENTER LINE OF COUNTER CUTOUT CENTER LINES OF DUCT CUTOUT 241 8 10 x 3 CUTOUT TYP 5 BOTTOM DISCHARGE RIGHT SIDE DISCHARGE LEFT SIDE DISCHARGE BOTTOM DISCHARGE RIGHT SIDE DISCHARGE ...

Страница 5: ...ELECTRICAL OUTLET If Models VIPR102SS or VIPR102RSS are being installed in a 30 wide cabinet or Models VIPR162SS or VIPR162RSS are being installed in a 36 wide cabinet or Models VIPR182SS or VIPR182RSS are being installed in a 48 wide cabinet the outlet cannot be located on the back wall of cabinet In these cases the width of the downdraft covers nearly the entire width of the back wall of the cab...

Страница 6: ...ditional screws supplied throughbottomflangetosecurebottomofdischarge plate NUTS COVER PLATE CLAMP CHANNELS SCREWS GEARMOTOR COVER MOTOR PLUG 10 ROUND DISCHARGE PLATE ADDITIONAL SCREWS BOTTOM FLANGE CUT COUNTERTOP OPENING All Units Must use island trim Rear countertop trim supplied with island trim will be used in this installation 1 Measure and cut the countertop opening for your width of cooktop...

Страница 7: ...e and air tight 3 Connect ductwork to downdraft If necessary LOOSEN nuts and screws that hold remote blower adapter plate in place and slide outlet assembly left or right to meet ductwork Re tighten screws and nuts LEVELING BRACKET FLANGE FACING IN LEVELING BRACKET FLANGE FACING OUT MOUNTING SCREWS MOUNT THE UNIT All Units CAUTION BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK check for interference ...

Страница 8: ...remote blower to wiring box on 10 round discharge plate 5 Connect downdraft wiring to power cable from remote blower Wire black to black white to white and green to green or bare wire 6 Replace wiring box cover 7 Plug the downdraft s power cord into outlet Make sure that the power cord is routed away from the heat generated by the cooktop CAUTION All electrical wiring should be done by a qualified...

Страница 9: ...e adhesive back of the control line the control up with the three holes and position the control so it is parallel with the front of the counter top Press down firmly for 60 seconds 4 Removethetwonylonthumbnutsfromtheplasticbagandthread onto the two studs on the control from below the counter top Hand tighten only The thumbnuts just need to be snugged by hand They are there to hold the control in ...

Страница 10: ...10 Downdraft Ventilators VIKING RANGE CORPORATION This page has been left blank intentionally BACKSIDE OF REMOTE SWITCH TEMPLATE All manuals and user guides at all guides com ...

Страница 11: ...UNT THE UNIT to remove the downdraft from the cabinet All Units OPERATION All Units UP DOWN Raisesandlowers vent Turns blower ON when vent is UP and OFF when vent is DOWN Note The UP DOWN switch for models VIPR102SS VIPR162SS and VIPR182SS is on the right hand end of the top cover DELAY Allows blower to run for 10 min after button is pressed Delay is activated by double press ing any speed control...

Страница 12: ... breach of warranty breach of contract or otherwise Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Owner shall be responsible for proper installation providing normal care and maintenance providing proof of purchase upon request and making the appliance reasonably accessible for service If...

Страница 13: ...de cuisine proportionnelle à l élément de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE DÉCLENCHE SUR LA SURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 ÉTOUFFEZ LES FLAMMES avec un couvercle hermétique une tôle à bis cuits ou un plateau en métal puis éteignez la cuisinière PRENEZ GARDE AUX BRÛLURES Si vous ne parvenez pas à éteindre immédiatement les flammes ÉVACU...

Страница 14: ...ace de cuisson COMPTOIR BOUCHE DE CHEMINÉE CONDUIT ROND DE 25 4 cm 10 po PLAQUE D ÉVACUATION DE 25 4 cm 10 po SPÉCIFICATIONS ÉLECTRIQUES 120 VCA 60 Hz 6 0 A max SPÉCIFICATIONS ÉLECTRIQUES 120 VCA 60 Hz 4 0 A PRISE DES MESURES Tous les appareils 1 Consultez les instructions d installation pour connaître les di mensions de la surface de cuisson du découpage à effectuer dans le comptoir et les exigen...

Страница 15: ...ONDUIT DROIT DE 61 CM 2 PI VUE DE CÔTÉ DE LA HOTTE AVEC VENTILATEUR INTÉRIEUR VIDV500 VUE DE CÔTÉ DE LA HOTTE AVEC COUDE ROND DE 25 4 cm 10 po pour connexion au ventilateur exté rieur VEDV900 ou VEDV1200 VENTILATEUR INTÉRIEUR VIDV500 Ventilateurs encastrés 74 6 cm 29 5 16 po DU COMPTOIR AU DESSOUS DU BOÎTIER 5 cm 2 po 45 7 cm 18 po 7 mm 1 4 po 5 4 cm 2 1 8 po 2 5 cm 1 po 9 2 CM 3 5 8 po 12 7 cm 5 ...

Страница 16: ...les câbles électriques et les tuyaux de nuisent pas Ventilateurs encastrés 61 2 cm 24 1 8 po LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR 14 cm 5 1 2 po LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNES DE CENTRE DU DÉCOUPAGE POUR CO...

Страница 17: ...sVIPR102SS ouVIPR102RSS sont installés dans une armoire de 76 2 cm 30 po de largeur ou les modèles VIPR162SS ou VIPR162RSS sont installés dans une armoire de 91 4 cm 36 po de lar geur ou les modèles VIPR182SS ou VIPR182RSS sont installés dans une armoire de 122 cm 48 po de largeur la prise ne peut pas être fixée au fond de l armoire Dans ce cas le boîtier de la hotte occupe presque toute la largeu...

Страница 18: ...NT AIRES BRIDE INFÉRIEURE DÉCOUPAGE DU COMPTOIR Tous les modèles Requiert une moulure d îlot La moulure arrière du comptoir fournie avec la moulure d îlot sert dans ce type d installation 1 Mesurez et découpez l ouverture du comptoir selon la largeur de la surface de cuisson et de la hotte Ventilateurs encastrés PLAQUE D ÉVACUA TION RONDE DE 25 4 cm 10 po Surface de cuisson 76 2 cm 30 po 91 4 cm 3...

Страница 19: ...a hotte Au besoin DESSERREZ les écrous et les vis qui maintiennent la plaque d adaptateur du ventilateur et glissez la à gauche ou à droite pour l aligner avec le conduit Resserrez les vis et les écrous BRIDE DE NIVELLE MENT REBORD À L INTÉRIEUR BRIDE DE NIVELLEMENT REBORD À L EXTÉRIEUR VIS DE MONTAGE INSTALLATION DE L UNITÉ Tous les modèles ATTENTION AVANT DE DÉCOUPER L AR MOIRE POUR LES CONDUITS...

Страница 20: ...que d évacuation de 25 4 cm 10 po de diamètre 5 Raccordez les fils de la hotte au câble d alimentation du ven tilateur Raccordez le noir avec le noir le blanc au blanc et le vert au vert ou au fil nu 6 Refermez la boîte électrique 7 Branchez le cordon électrique de la hotte dans la prise Assurez vous que le cordon est loin de la chaleur dégagée par la surface de cuisson ATTENTION Le câblage doit ê...

Страница 21: ...on chaudpourraitêtredéposéoudesliquideschaudsrenversés 4 Sortez les deux écrous en nylon du sachet de plastique et installez les sur les goujons de la télécommande en dessous du comptoir Serrez à la main seulement Les écrous à oreilles doivent être bien appuyés mais seulement à la main et ne servent qu à maintenir la télécommande jusqu à ce que l adhésif soit sec 5 Sortez le câble du sachet et bra...

Страница 22: ... Downdraft Ventilators VIKING RANGE CORPORATION Ventilateurs encastrés Cette page a été laissée en blanc volontairement ARRIÈRE DU GABARIT DE LA TÉLÉCOMMANDE All manuals and user guides at all guides com ...

Страница 23: ... Tous les modèles HAUT BAS R e l è v e o u abaisse le con duitd aération Met le ventilateur en MARCHE lorsque le conduit est RELEVÉ et ARRÊTE le ventilateur lorsque le conduit est ABAISSÉ Remarque Le bouton HAUT BAS UP DOWN des modèles VIPR102SS VIPR162SS et VIPR182SS est situé à droite de la télécommande DÉLAI Actionne le ventilateur pendant 10 minutes une fois que l on a appuyé sur le bouton Le ...

Страница 24: ...on d un contrat ou de toute autre cause Certaines juridictions interdisant l exclusion ou la limitation des dommages indirects ou consécutifs il se peut que la limitation ou l exclusion ci dessus ne s applique pas à vous Le propriétaire a la responsabilité d installer et d entretenir correctement le produit de présenter sa facture sur demande et de veiller à ce que l appareil soit suffisamment acc...

Страница 25: ...e use utensilios de cocina que sean apropiados para el tamaño del elemento de la superficie TPARA REDUCIR EL RIESGO DE LESIONES A PERSONAS EN CASO DE UN INCENDIO PRODUCIDO POR GRASA EN UNA ESTUFA OBSERVE LO SIGUIENTEa 1 APAGUE LAS LLAMAS con una tapa de ajuste exacto una charola para galletas o una bandeja de metal y después apague el quemador PROCEDA CON CUIDADO PARA EVITAR QUEMADURAS Si las llam...

Страница 26: ... unidad en el gabinete Instale la placa de descarga redonda de 10 pulg 25 cm Instale el ventilador exterior modelo VEDV900 o VEDV1200 sólo el modelo de 48 pulg 120 cm Conecte los conductos y el sistema eléctrico Instale la estufa PLACA DEL CONDUCTO REDONDO DE 10 pulg 25 cm CONDUCTO REDONDO DE 10 pulg 25 cm ESPECIFICACIONES ELÉCTRICAS 120 VCA 60 Hz 4 0 A TOME MEDIDAS Todas las unidades 1 Consulte l...

Страница 27: ... consideración la longitud equivalente en pies de varias tapas de techo y pared No las incluya en este cálculo TRANSICIÓN REDONDA DE 3 1 4 X 10 pulg 8 2 x 25 cm A 6 pulg 15 2 cm 1 pulg 2 54 cm LA PARTE SUPERIOR DEL GABINETE HASTA LA PARTE INFERIOR DE LA CAJA DE AIRE 7 11 16 pulg 19 53 cm 2 pulg 5 cm 1 4 pulg 64 cm 2 1 8 pulg 5 4 cm 3 1 4 pulg 8 26 cm 3 5 8 pulg 9 2 29 5 16 74 4 cm 5 pulg 12 7 cm 1...

Страница 28: ...RAL DEL CORTE PARA EL CONDUCTO 2 pulg 7 cm RECORTE REDONDO DE 10 pulg 25 cm Típico 3 pulg 8 9 cm 6 pulg 15 9 cm LÍNEA CENTRAL DEL CORTE DEL CONDUCTO se puede situar dentro de esta área 10 pulg 26 cm LÍNEA CENTRAL DEL CORTE PARA EL GABINETE 10 pulg 26 cm RECORTE REDONDO DE 10 pulg 25 cm Típico LÍNEAS CENTRALES DEL CORTE PARA EL CONDUCTO 19 pulg 50 17 cm LÍNEA CENTRAL DEL CORTE PARA EL GABINETE LÍNE...

Страница 29: ...ar en un gabinete de 30 pulg 75 cm de ancho o si los modelos VIPR162SS o VIPR162RSS se van a instalar en un gabinete de 36 pulg 90 cm de ancho o si los modelos VIPR182SS o VIPR182RSS se van a instalar en un gabinete de 48 pulg 120 cm de ancho el tomacorriente no puede estar en la pared posterior del mueble En estos casos la anchura del tiro descendente cubre casi la totalidad de la anchura de la p...

Страница 30: ...10 pulg 25 cm TORNILLOS ADICIONALES REBORDE INFERIOR HAGA LA ABERTURA DE LA SUPERFICIE DEL GABINETE Todas las unidades Debe usar la tira de adorno de la isla En esta instalación se usará la tira de adorno de la superficie del gabinete trasera incluida con la tira de adorno de la isla 1 Mida y corte la abertura de la superficie del gabinete según el ancho de la estufa y del tiro descendente A C B D...

Страница 31: ...Si es necesario AFLOJE las tuercas y los tornillos que fijan la placa adaptadora del ventilador remoto en su lugar y deslice el conjunto de la salida hacia la izquierda o hacia la derecha para que se una con los conductos Vuelva a apretar los tornillos y las tuercas SOPORTE DE NIVELACIÓN REBORDE ORIENTADO HACIA ADENTRO SOPORTE DE NIVELACIÓN REBORDE ORIENTADO HACIA AFUERA TORNILLOS DE MONTAJE MONTE...

Страница 32: ...una placa de descarga de 10 pulg 25 cm 5 Conecte el cableado del tiro descendente al cable eléctrico desde el ventilador remoto Conecte negro con negro blanco con blanco y verde con verde o con el hilo desnudo 6 Vuelva a colocar la cubierta de la caja 7 Conecte el cable eléctrico del tiro descendente en el tomacorriente Asegúrese de que el cable eléctrico esté tendido lejos del calor generado por ...

Страница 33: ...control de tal manera que quede paralelo con el frente del gabinete Oprima firmemente durante 60 segundos 4 Saque las dos tuercas de mariposa de nailon de la bolsa de plástico y enrósquelas en los dos pernos del control desde debajo del gabinete Apriete las tuercas sólo con la mano Las tuercas de mariposa sólo tienen que apretarse con la mano Están ahí para mantener en su lugar al control hasta qu...

Страница 34: ...ntiladores de tiro descendente VIKING RANGE CORPORATION Esta página se ha dejado en blanco intencionalmente PARTE POSTERIOR DE LA PLANTILLA DEL CONMUTADOR REMOTO All manuals and user guides at all guides com ...

Страница 35: ...das las unidades FUNCIONAMIENTO Todas las unidades ARRIBA ABAJO Subeybajaelsistema de ventilación Enciendeelventilador cuando el sistema está ARRIBA y lo apaga cuando el sistema está ABAJO Nota El interruptor ARRIBA ABAJO para los modelos VIPR102SS VIPR162SS y VIPR182SS se encuentra en la parte inferior derecha de la cubierta superior RETRASO Permitequeelventiladorfuncionedurante10minutos después ...

Страница 36: ...es no permiten la exclusión o limitación de daños incidentales o consecuentes por lo que la limitación o exclusión antes mencionada podría no aplicarse a usted El propietario será responsable de la instalación adecuada de suministrar el cuidado y el mantenimiento normales de presentar un comprobante de compra previa solicitud y de hacer que el electrodoméstico sea accesible razonablemente para el ...

Отзывы: