•Maximum duct run length: 50 Ft. (152.4 cm)
•All CFM’s stated are based on tests with .1 static pressure; without applying static pressure (as some brands consciously do), CFM
could be greatly overstated.
•Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
•Straight runs and gradual turns are best; avoid sharp turns; for example, each 90
0
elbow is equivalent to 5 - 10 feet (1.52 m - 3.05
m) of straight run.
•NEVER USE FLEXIBLE DUCT; It creates back pressure / air turbulence and greatly reduces performance.
•Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
•Check with a qualified and trained installer or local codes for makeup air requirements, if any.
S
Sp
pe
ecciiffiiccaattiio
on
nss
3
30
0”” W
W.. M
Mo
od
de
ell
3
36
6”” W
W.. M
Mo
od
de
ell
Exhaust Capacity
460 CFM
460 CFM
Blower Motors
1
1
Electrical Requirements
5.6 amps
5.6 amps
(120VAC/60Hz)
Ducting Requirements *
7” (17.8 cm) round
7” (17.8 cm) round
Mesh Filters
2
2
Charcoal Filters**
2
2
Spacers
0
1
Halogen Lights (50W)
2
2
BASIC SPECIFICATIONS - 12”H. CHIMNEY HOODS
*Disregard when using
recirculating kits
**Recirculating kits only
3
HEIGHT OF HOOD
The bottom of the hood should be 30” (76.2 cm)
min. to 33” (83.8 cm) max. above the countertop. This
would result in the bottom of the hood being 66” (167.6
cm) to 69” (175.3 cm) above the floor. These dimensions
provide for safe and efficient operation of the hood and a
more proportionately pleasing and attractive installation.
24”
(61.0 cm)
12” (30.5 cm)
30” (76.2 cm) min.
33” (83.8 cm) max.
36”
(91.4 cm)
66” (167.6 cm)
to
69” (175.3 cm)