![Viking Electronics K-1775-BN-IP Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/viking-electronics/k-1775-bn-ip/k-1775-bn-ip_product-manual_1026060011.webp)
11
Programming Features Index
DESCRIPTION
Section
Page
Connect/Disconnect
1
12
Phone Number Database
2
13
Event Log
3
14
Entry Code Database
4
15
Phone Name
5
15
Mute Alarm Until Next Failure
6
15
Phone Firmware
7
15
IP Firmware
8
15
Import/Export
9
16
Factory Default
10
16
Diagnostics (used to check mic, speaker, relays and proximity card reader operation)
11
16
Security code (factory set to 845464)
12
16
Access Code (1-6 digits, blank = disabled, factory set to 123456)
13
16
Auto Answer / Loud Ring (Disabled, Auto Answer, Loud Ring, Loud Ring with AGC, factory set to Auto Answer)
14
16
Ring Cadence (factory Set to Normal Ring)
15
16
Loud Ring Volume (0-9, 1 - low, 9 - high, 0 = disabled, factory set to 5)
16
16
Phone Mode (Auto Dialer or Manual Dial Phone, factory Set to Auto Dialer)
17
17
Call Button Delay
18
17
Call Button Auto Dial
19
17
Select Time Zone
20
17
Daylight Savings
21
17
Keyless/Card Logging
22
17
Relay 1 or 2 Mode (Door Strike, Outbound Call, In/Outbound Call, Doorbell, Alarm Mode, factory set to Door Strike)
23
18
Relay 1 or 2 Command (1 or 2 digits, factory set to
and
Q
2) (Relay Mode must be set to Door Strike)
24
18
Relay 1 or 2 Time (0.5 - 99 sec, factory set to 5 sec)
25
18
Relay 1 or 2 Int/Ext (factory set to Internal)
26
18
Relay Act. Delay (Disabled or 0.5 - 99 sec, factory set to Disabled)
27
18
Relay Buzz (Activation Tone) Volume (1 digit 0-3, 0 = off, factory set to 3)
28
19
Latch Commands (Enabled or Disabled, factory set to Enabled)
29
19
Speaker Mode (OFF/Silent Monitor or ON, factory set to ON)
30
19
Speaker Volume (0-9, factory set to 2)
31
19
Microphone Volume (0-9, 0 = ANC, factory set to 5)
32
19
Talk/Listen Delay (VOX) (.1 to .9 sec, factory set to .5 sec)
33
19
Audio Call Progress (OFF, ON, factory set to ON)
34
19
Audio Detect Level (1-9, 1 = min, 9 = max, factory set to 5, power cycle unit after setting)
35
19
Call Length Time Out (disabled or 1 to 9 min, factory set to 3 min)
36
20
Dial Next # on RNA (Ring No Answer) (disabled, 1 - 9 = number of rings, factory set to 7)
37
20
Dial Next # on Busy (disabled or enabled, factory set to enabled)
38
20
Live Dialing Format ( Inband DTMF or RFC2833, factory set to RFC2833)
39
20
REX Input
40