9
C. Configuring the 40TB-IP Network Settings
Step 1.
Open the “Viking IP Programming” software on a windows PC that is connected to the same LAN as the
40TB-IP
phone to be
programmed.
Step 2.
The window in the upper left corner of the menu will show you each
40TB-IP
phone that is connected to that LAN. Select the unit with
the same MAC address shown on the label located on the top of the Ethernet connector on the
40TB-IP
phone.
Step 3.
Click the “Connect” button. If a pop up window appears, enter the unit’s security code (factory set to
845464
) then click “OK”.
Step 4.
The program will then read and display the
40TB-IP
phone’s IP and programming settings.
Step 5.
Click on the “IP Settings” tab and fill in the three required fields of SIP Server, Username and Password. The SIP provider or the phone
system programmer provide the information to put in these fields. The SIP Server field can contain an IP address or a fully qualified
domain name. Some examples are shown below. Our phones use port “5060” for traffic by default but another port can be specified by
adding a “:” (colon) and the desired port number at the end of the SIP server IP address (for example “192.168.210.61:5070” to specify
port “5070”). You can also assign a name for the
40TB-IP
in the Unit Name field. When finished, click on the “Apply” button to send the
IP settings to the connected unit. See Examples 1 and 2 of the required fields below:
Step 1.
Power down the
40TB-IP
phone by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Press and hold the CALL button, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Continue to hold CALL button until you hear 2 beeps, (approximately 6 seconds). Then release the button. The LED will remain off for
the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2 beeps), indicating when to release button.
Step 4.
The security code is now reset to
845464
(factory default).
Step 5.
You can now enter programming by following the steps in section
A
.
D. Manually Resetting the Security Code to Enter Programming
E. Manually Resetting All Network Parameters to Factory Default
Step 1.
Power down the
40TB-IP
phone by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Press and hold the CALL button, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Continue to hold t he CALL button until you hear 2 beeps, (approximately 6 seconds). Continue to hold CALL button until you hear 4
more beeps, approximately 6 seconds later, then release the button. The LED will remain off for the first 3 seconds, flash slowly for 3
seconds (2 beeps), fast flash for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4.
You can now enter programming by following the steps in section
A
.