background image

Vigilant Inc. 

Reliance End Table 

Owner’s Manual, Page 

 

 

MAINTENANCE 

1.

 

Your Vigilant cigar cabinet is more than just a cigar humidor; it is a fine piece of 
handcrafted furniture. Regularly dust the exterior of the cabinet by spraying a soft 
cloth and a product like Endust. Please do not spray your cabinet with furniture polish, 
as the polish will eventually build up and dull the beautiful hand- finish on the cabinet. 

2.

 

When the RED time -to-fill LED or LOW WATER alarm is on, it is time to fill the water 

tray with distilled water. Frequency of filling will depend on ambient conditions. 

3.

 

You will find a trap door on the inside of your cabinet. Lifting up this panel will provide 

access to the water tray. Pour distilled water in the large front cutout of the water tray 

until the alarm goes out. 

DO NOT overfill the water tray or pour water on any of the 

electronics. 

4.

 

Be sure to keep boxes free from the fan in the back as well as the front grommet 

holes. Failure to do so could cause issues with humidity levels. 

 

Never move the cabinet when water is in the water tray. 

Never pick the cabinet up by its top. 

 

CLEANING THE RESERVOIR AND WICK 

As both the reservoir and wick are constantly exposed to moisture, and the wick is exposed 

to dirt and other airborne particles, they must be cleaned periodically. It is recommended 

that you check the water and reservoir at least once every three months. 

1.

 

It is advised to unplug your cabinet prior to cleaning the reservoir and wick. 

2.

 

Lift the trap door and secure in position with the lever on the sidewall of the 

cabinet. You will need to remove all water from the water tray and remove the 

wicking filter. 

3.

 

Once the trap door is opened and secured with the clip, unplug the float switch. If 

there is any remaining water in the water tray, it can be removed with a sponge. 

4.

 

The reservoir can then be removed from the cabinet for cleaning. You can open the 

reservoir by the 2 clips on the side of the box. Rinse thoroughly with warm water and 

dish soap. DO NOT USE BLEACH. The wicking filter can be rinsed and used again. If the 

wicking filter does not wash clean, it should be replaced. It is recommended to replace 

the wicking filter every 3-4 months. 

5.

 

Put the reservoir back in its place and reconnect the float switch wire. Once wicking 

filter is back in place, lower trap door while making sure no wires are in the way. 

6.

 

You can now plug your cabinet back in. 
 

 

IF WATER IS SPILLED WHILE REFILLING THE RESERVOIR, 

DO NOT PLUG YOUR CABINET BACK IN UNTIL IT IS COMPLETELY DRY. 

PLUGGING THE CABINET IN BEFORE IT IS DRY COULD CAUSE FAILURE 

OF THE CONTROLLER AND OTHER ELECTRONIC COMPONENTS 

Содержание HumiDoor 75

Страница 1: ...Desktop Series Owner s Manual...

Страница 2: ...ic humidification system will be yours to enjoy for generations Please read this entire manual before powering and operating your cigar cabinet By following these instructions you will not only ensure...

Страница 3: ...cabinet that is away from any source of heat or other climate control devices Placement in front of or close to items such as radiators heating elements air conditioning ducts or direct sunlight will...

Страница 4: ...l depend on the ambient conditions The longest stabilization is required when the ambient parameter is near full scale typically no longer than 24 hours Alarms The Guardian control is equipped with se...

Страница 5: ...ICON KEY Cabinet Lights Circulation Fans Heating Cooling Humidification Dehumidification Optional Equipment Icons will only appear on screen when the feature is ON or active TEMP 70F RH 70...

Страница 6: ...no key is pressed for 20 seconds the display will return to the home screen Press and hold the key anywhere in the user menu for 3 seconds to force return to the home screen Indexing after the last op...

Страница 7: ...and Dehumidification DRH Dehumidification is optional equipment DRH outputs may be disabled Relative Humidity RH offset Raise RH Offset Lower RH Offset Factory may adjust during set up Use this numbe...

Страница 8: ...Settings Continued Brightness Raise Brightness Lower Brightness Contrast Raise Contrast Lower Contrast BRIGHTNESS 100 CONTRAST 50...

Страница 9: ...ay turns off after 20 seconds Wakes up with button press DIM Display dims to 25 of set brightness after 20 seconds Wakes up with button press See recorded MIN MAX levels Press to show MIN MAX Press ag...

Страница 10: ......

Страница 11: ...er spills in the cabinet IMPORTANT Once connected to power the Guardian control will begin a 10 minute stabilization program Ignore any alarms and continue with the follow steps 2 Lift the wood door p...

Страница 12: ...e wick is exposed to dirt and other airborne particles they must be cleaned periodically It is recommended that you check the water and reservoir at least once every three months 1 It is advised to un...

Страница 13: ...unning constantly and not raising the humidity A Make sure that your wicking filter is fresh and clean Check for obstructions over the fan Be sure there is at least a 2 gap open in the back of the cab...

Страница 14: ...imitedtwo year warranty All Vigilant electronic products are guaranteed to be free from defects in materials and or workmanshipforuptotwoyearsfromdateofpurchase Vigilant atitssolediscretion mayrepairo...

Страница 15: ...sedbyneglect abuse misuse improper operation or acts of God Vigilant swarrantyisconsiderednullandvoidifsubmittalofyour link warrantyregistrationonlineisnot completed within 60 days from receipt of you...

Страница 16: ...Vigilant Inc Reliance End Table Owner s Manual Page Copyright 2017 Vigilant Inc All rights reserved...

Отзывы: