background image

 

Page 

6

 of 

6

 

 

MCU_1-I/P_ User Manual 

 

 

 

 

 

 

 

 

V1.0 

6. Do’s & Don’ts When Fire Occurs 

Do’s

 

If the Fire is severe, it is very dangerous for anybody to enter the premises. 

 

If there is a minor/moderate Fire - Turn off the knob, regulators . 

 

Open all doors & windows. 

 

Don’ts

 

Do not panic 

 

Do not OFF/ON any electrical switch. 

 

7. Warranty

 

Realty Automation and Security Systems PVT. Ltd

 products are warranted for 12 months subjected to 

following terms and condition.

 

 

 

This limited warranty covers defects in materials and workmanship in this product, it does not cover 

any malfunction occurred due to transportation, wrong material handling practice, wrong wiring, 

voltage and current fluctuations etc.

 

 

Consumable parts such as cables, cords, stickers etc. are not subjected to warranty. 

 

 

This limited warranty covers only the original purchaser of the product. The limited warranty is not 

transferable to subsequent owners or purchasers of this product 

 

 

The limited warranty does not assume the risk of loss during shipment.

 

 

Warranty does not include fuses, disposable batteries or the routine replacement of parts due to 

normal wear and tear of the product

 

Product warranty void if

 

 

Any damage or defects attributable to repair of the product by any person other than an authorized 

dealer, or the installation of unapproved parts on the product

 

 

LCD/LED crushed or bleeding

 

 

War  page to the main PCB as a result of crushing

 

 

Fluid ingress as a result of submergence beyond the I.P rating specification

 

 

If not followed: proper storage, installation, calibration, use, maintenance and compliance with the 

product manual instructions and any other applicable recommendations of Realty Automations and 

Security Systems PVT. Ltd

 

Limited Warranty Liability:

 If in case, due to any reason if the product does not function as per the 

desired specifications, then the manufacturer will not be responsible for any liability/damages arises 

because of its non-function. In any case manufacturer will not be able to pay the compensation beyond 

the selling price of manufacturer, which needs to be shown in terms of selling/buying invoice in terms of 

Indian Rupees. For exports warranty claims, invoiced date should be considered for deriving rate of INR 

= USD. In any case warranty claim will not be accepted beyond unit value of the products sold as per the 

invoice. Manufacturer/seller does not take any responsibility of any damages which arises because of 

timely non-function of the product.

 

To and fro transportation cost till the centre/factory at Pune to be borne by the customer.

 

For all warranty claims customer need to produce invoice/warranty certificate.

 

Содержание Master Control Unit

Страница 1: ...y System Pvt Ltd 2nd Floor Karanjakar Industrial Estate Sr No 11 11 Nanded Gaon Pune Phone no 91 20 32922630 32921306 Fax 91 20 24339628 Website http www vighnaharta in Prepared by HC Approved By Doc No RASS R D Master Control Unit1_UM_1_0 Rev No 1_0 Eff Date 14 10 2019 USER MANUAL FOR Master Control Unit VERSION 1 0 ...

Страница 2: ... not defined Salient Features 3 2 Technical Specifications 3 3 Installation Instructions 4 Pre installation Checklist 4 Locations to be avoided for installing Master Control Unit 4 4 Operation Error Bookmark not defined 5 Wiring Diagram 5 6 Do s Don ts When Fire Occurs 6 7 Warranty 6 ...

Страница 3: ...ounder becomes OFF for 30 seconds after 3 minutes and again becomes ON This feature is for protecting the sounder from over heating and damage Two PFC outputs for interfacing the other systems LED Indications for MAINS ON SYSTEM HEALTHY GAS Release 1 ALARM SILENCE Easy installation operation and maintenance free MS sheet housing and powder coated enclosure 2 Technical Specifications Electric speci...

Страница 4: ...en digital inputs are closed Fire is below pre defined level LEDs 1 Mains ON LED ON 2 System Healthy LED ON 3 GAS Release 1 Alarm LED OFF 4 Relay LED OFF Hooter with Flasher OFF 2 When digital input 1 is open Digital input 1 is opened LEDs 1 Mains ON LED ON 2 System Healthy LED OFF 3 GAS Release 1 Alarm LED ON 4 Relay LED ON Hooter with Flasher ON Silence Switch Silence switch can be used to silen...

Страница 5: ...iring Diagram A PFC Output ON 1 NO B PFC Output ON 1 Common C PFC Output ON 1 NC D PFC Output ON 2 NO E PFC Output ON 2 Common F PFC Output ON 2 NC G DC 12V H DC 12V I Flasher Sounder ve J Flasher Sounder ve K NA L NA M Digital Input 1 ve N GND ...

Страница 6: ...duct by any person other than an authorized dealer or the installation of unapproved parts on the product LCD LED crushed or bleeding War page to the main PCB as a result of crushing Fluid ingress as a result of submergence beyond the I P rating specification If not followed proper storage installation calibration use maintenance and compliance with the product manual instructions and any other ap...

Отзывы: