39
VIGAS 18 DPA, VIGAS 26 DPA
Gasifying boilers VIGAS
Commission Regulation (EU) 2015/1189,implementing Directive 2009/125/EC of the European Parliament and of the
Council with regard to ecodesign requirements for solid fuel boilers, commission Regulation (EU)2015/1189
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of
solid fuel boilers.
Product information
Symbol
Unit
VIGAS 18
DPA
VIGAS
26 DPA
Energy efficiency class
A++
A++
Coefficient of energy
EEI
127
130
Seasonal Energy efficiency heating area
η
s
%
87
89
Mode skoting
Automatic
Boiler is recommended to operated from a reservoir
least
L
500
800
Condensing boiler
nie
nie
Combined boiler
nie
nie
Preffered fuel
Laminated wood in the form of pellets
Charactericstic when operating with preffered fuel
Useful thermal output at rated power
P
n
kW
18,0
26
Useful efficiency at rated power
η
n
%
91,87
92,83
Useful thermal output at minimum output / <50%
P
p
kW
4,4
6,6
Useful efficiency at minimum output
η
n
%
90,39
91,74
Own electricity consumption at rated power
el
max
kW
0,085
0,130
Own electricity at minimum output
el
min
kW
0,014
0,010
Own electricity consumption in standby mode
P
SB
kW
0,001
0,001
Own electricity consuption in firing mode
Pzap
kW
1,773
1,693
Sezonne emissions heating area TČ
1)
PM
mg/m
3
13,2
21,0
Sezonne emissions heating area POZ
1)
OGC
mg/m
3
14,4
19,7
Sezonne emissions heating area CO
1)
CO
mg/m
3
260,9
360,5
Sezonne emissions heating area NOx
1)
NOx
mg/m
3
156,1
139,3
Characteristic when operating with substitute fuel
Substiture fuel
Chopped wood ,moisture content 20%
Useful thermal output at rated power
P
n
kW
24,0
36,0
Useful efficiency at rated power
η
n
%
91,57
91,41
Useful thermal output at minimum output / <50%
P
p
kW
10,0
15,0
Useful efficiency at minimum output
η
n
%
90,95
90,10
Own electricity consumption at rated power
el
max
kW
0,030
0,038
Own electricity at minimum output
el
min
kW
0,005
0,012
Own electricity consumption in standby mode
P
SB
kW
0,001
0,001
Season emissions of the heating space TČ
2)
PM
mg/m
3
42,8
22,7
Season emissions of the heating space OGC
2)
OGC
mg/m
3
28,3
28,2
Season emissions of the heating space CO
2)
CO
mg/m
3
370,6
456,4
Season emissions of the heating space NOx
2)
NOx
mg/m
3
221,6
150,0
1. Preffer fuel: Chopped wood, moisture content 20%
Information sheet with data on the energy consumption of products
VIGAS 18 DP
A
, 0032/104/2015
VIGAS 26 DP
A