WIRING (only 24V~ inputs)
1. On the back of the monitor, loosen the thumb screws and lower the access panel.
2. Attach the leads from the power supply (not supplied) to the left and right connectors.
WARNING: Do not connect a ground to the center post.
3. When finished, secure the access panel.
Table A shows the recommended maximum wiring distances (transformer to load),
and are calculated with a 10-percent voltage drop.
(10 percent is generally the maximum allowable voltage drop for AC-powered devices.)
Recommended Wiring Distances
Inch
Wire
18AWG
16AWG
14AWG
26
”
60 ft
(18 m)
120 ft
(36 m)
150 ft
(45 m)
32
”
30 ft
(9 m)
30 ft
(9m)
90 ft
(27 m)
6