2. Firmware Upgrade Procedure
When you receive the returned monitor, please check whether the firmware version is the
latest. If not, please do the following procedures to upgrade it to the latest version.
2.1. Equipment Needed
- VA902/b-3 Monitor
- Fixture for Firmware Upgrade
- VGA Cable
- PC (Personal Computer)
- LPT Cable
- Firmware Upgrade Program
- One additional monitor for checking the program execution
PC
VGA Cable
Printer Port
LPT Cable
VA902/b-3
ViewSonic Corporation
Confidential - Do Not Copy
VA902-3_VA902b-3
24