3.1 PWM Control
12.
Control the gimbal camera functions by the multiplex pulse width
modulation signal outputted by PWM channel of the remote control
receiver. The camera needs up to 6 control channels of PWM (to
expand tracking function use up to 7 PWM channels). You can choose
needed functions according to actual usage to reduce the required
number of PWM channels.
3.1.1 PWM Connection Diagram
(Connect pitch chan-
nel as example)
3. Signal Control
Above output mode is optional. Please subject to
your actual product.
When using user interface software Viewlink for
network connection, the network of external device
(computer) should be the IP address: 192.168.2.2
(choose the last byte among 2~254, can not be 119
same as the gimbal), subnet mask: 255.255.255.0,
Default gateway: 192.168.2.1, and all firewalls of the
computer must be closed. Then enter the IP address
of the gimbal camera, Open Video, the video stream
can be outputted.