Clock thermostat
Rated voltage
3 V
–
2 batteries LR 6
Switching hysteresis
0.4 to 1.5 K
Power consumption
2 W
Protection class
II
Protection
IP 20
Ambient temperature
&
during operation
5 to 40 °C
&
during storage and transport
-20 to 40 °C
Function
Type 1B to EN 60730-1
Wireless receiver
Reception frequency
868 MHz
Power supply
from the control unit
Ambient temperature
0 to 55 °C
Protection
IP 20 to EN 60529
Protection class
II to EN 60730-1
&
The clock thermostat transmits:
–
with every heat demand and con-
sumption
–
with each changeover of the time
switch for DHW heating
–
and cyclically every 30 min
&
All switching data are saved in non-
volatile form in case of power fail-
ure.
No heat demand is executed during
power failure.
Specification
15
53
55
246