background image

Vitosol 100-F Technical Data

5354 729 - 01

 Standard Equipment/Accessories

                     Technical information subject to change without notice.

Printed on environmentally friendly  (recycled and recyclable) paper.

Standard equipment

Vitosol 100-F, Models SH1B and SV1B come fully 

assembled in shrink-wrap packaging and ready to be 

connected.

Accessories

Accessories (individually packed, depending on order):

- Mounting hardware with technical literature

- Interconnection pipes with insulation

- General connection set

- Sensor well set

- Solar Divicon (pumping station for the collector circuit)

- Electronic differential temperature control

- Automatic air vent with air separator

- Fast air vent valve with tee and shutoff valve

- System filling manifold

- Solar hand pump

- Solar expansion tank

- Heat transfer medium

Mounting hardware

The mounting hardware consists of components required 

for the relevant method of installation, such as: 
Roof brackets, mounting plates, mounting rails, 

connecting elements for mounting rails, clamping bolts, 

screws and nuts.

General connection set

Required to connect solar collector to system piping. 

One set required per collector array - max. 269 ft

2

 (25 m

2

).

Pipe connection set

Required to connect multiple solar collectors.

Sloped roof hardware

Required for mounting collector directly onto shingled 

roof. Raises collector 3½”

(889 mm) above the roof.

Flat roof hardware

Required for freestanding, flat roof installations.

Solar Divicon

Preassembled pumping station for solar collector circuit.

Includes: 3-speed pump (2 sizes), pressure gauge, 

2 thermometers, 2 ball valves, pressure relief valve, 

flow meter, 2 flow check valves, air separator, system 

fill manifold, and foam insulation cover.

Note:

  Viessmann offers complete solar heating system    

  

 combi packages, as well as comprehensive design   

         support in order to facilitate the component 

 

 selection process.

SCU 124/224/345

Electronic differential temperature control for solar heating.

Roof bracket

Installation rail

x2

Heat transfer medium

Tyfocor non-toxic heating liquid for solar heating systems 
with active anti-corrosion and anti-ageing protection.
Frost protection:...................... to -31ºF (-35ºC)

Specific gravity at 68ºF (20ºC):... 1.032 to 1.035 g/cm

3

 

 to ASTM D 1122

Viscosity at 68ºF (20ºC):.......... 6.5 to 8.0 mm

2

/s to DIN  

  

51562 

pH value:................................ 7.5 to 8.5 to ASTM 

 

 D 1287

Color:..................................... transparent, blue-green

Container:............................... 5.3 USG (20 L) in a    

 

 disposable container

Содержание VITOSOL 100-F SV1B

Страница 1: ...vertical or horizontal installation on sloped and flat roofs To produce domestic hot water or to supplement low temperature heating systems or swimming pools via a heat exchanger VITOSOLr 100 F Product may not be exactly as shown Flat plate solar collectors for the harnessing of solar energy Panels with 25 ft 2 2 32 m2 absorber surface RAL UZ 73 ...

Страница 2: ...radiation and low emission of thermal radiation A meander shaped copper pipe through which the heat transfer medium flows is permanently embedded into the absorber The heat transfer medium channels the absorber heat through the copper pipe The absorber is encased in a highly insulated collector housing which minimizes collector heat losses The high quality thermal insulation provides temperature s...

Страница 3: ...7 6 Maximum stagnation temperature 5 F C 395 196 395 196 Connection in mm 22 22 Requirements for installation surface and anchorage Roof construction with adequate load capacity for prevailing wind forces 1 Important for system design considerations 2 Dimensions rounded to the nearest inch 3 Based on absorber surface area 4 In sealed systems operating pressure of at least 15 psig 0 45 psig x stati...

Страница 4: ...tor to system piping One set required per collector array max 269 ft2 25 m2 Pipe connection set Required to connect multiple solar collectors Sloped roof hardware Required for mounting collector directly onto shingled roof Raises collector 3 889 mm above the roof Flat roof hardware Required for freestanding flat roof installations Solar Divicon Preassembled pumping station for solar collector circ...