Dimensions
Capacity
120 l
150 l
with casing to
cover
connecting pipes
with casing to
cover
connecting pipes
a
mm
618
623
661
667
b
mm
904
1055
932
1055
c
mm
875
875
902
902
d
mm
122
128
144
150
e
mm
143
149
165
171
f
mm
214
220
235
241
g
mm
339
345
360
366
h
mm
430
436
452
458
k
mm
Ø 553
564 Ø 596
607
l
mm
2186
2186
2186
2186
m
mm
2255
2255
2255
2255
n
mm
126
191
148
213
o
mm
183
248
205
270
p
mm
276
341
298
363
Pressure drop on the DHW side
20
30
40
50
60
100
80
200
300
400
500
600
800
1000
2000
300
400 500 600
800 1000
2000
3000
4000
DHW volume in litres/h
Pressure drop in mbar
DHW output at rated boiler output
Rated output
for DHW heating
kW
18
22
18
22
Continuous DHW output
kW
18
22
18
22
for DHW heating from 10 to 45 ºC
and an average boiler water temper-
ature of 78 ºC
l/h
440
540
440
540
Performance factor N
L
to DIN 4708
Cylinder capacity 120 l
1.2
1.2
1.2
1.2
Cylinder capacity 150 l
1.6
1.6
1.6
1.6
Peak output
over 10 min
Cylinder capacity 120 l
l/10 min
153
153
153
153
Cylinder capacity 150 l
l/10 min
173
173
173
173
Delivered condition
Vitocell 100-W, type CUG
120 and 150 litre capacity
DHW cylinder made from steel with Ceraprotect enamel coating.
■ Welded sensor well for cylinder temperature sensor
■ Threaded adjustable feet
■ Protective magnesium anode
■ Fitted thermal insulation made from rigid PU foam
The colour of the epoxy-coated sheet steel casing is white.
Separate DHW cylinder for the Vitoladens 300-W
(cont.)
VITOLADENS 300-W
/
VITOLADENS 333-F
VIESMANN
15
5822 425 GB