56
897.0 "Screed drying"
Setting
Explanations
Not active
0
Screed drying can be set in accordance with selecta-
ble temperature/time profiles. For individual profile
curves, see chapter "Function description".
Diagram 1
2
Diagram 2
3
Diagram 3
4
Diagram 4
5
Diagram 5
6
Diagram 6
7
912.0 "Automatic summer/wintertime changeover"
Setting
Explanations
No
0
Automatic changeover disabled
Yes
1
Automatic changeover enabled
912.1 "Earliest day of changeover from winter to summertime"
Setting
Explanations
25
Changeover from 02:00 h to 03:00 h occurs on the
Sunday after or on this set date.
1 to 31
Day of changeover adjustable from 1st to 31st of the
month
912.2 "Month of changeover from winter to summertime"
Setting
Explanations
3
Month of changeover: March
1 to 12
Month of changeover adjustable from January to De-
cember
912.3 "Earliest day of changeover from summer to wintertime"
Setting
Explanations
25
Changeover from 03:00 h to 02:00 h occurs on the
Sunday after or on this set date.
1 to 31
Day of changeover adjustable from 1st to 31st of the
month
912.4 "Month of changeover from summer to wintertime"
Setting
Explanations
10
Month of changeover: October
1 to 12
Month of changeover adjustable from January to De-
cember
1098.4 "Gas volume correction factor"
Setting
Explanations
Value is provided on the gas supplier's bill.
Used for gas consumption data.
1.0000
0.7000 to
1.0000
Gas volume correction factor adjustable from 0.7000
to 1.0000 in increments of 0.0001.
Round the value up or down if necessary.
System configuration (parameters)
General
(cont.)
6130884
Parameter