179
Settings and actual values
Set value Commis-
sioning
Mainte-
nance/
Service
Date
Signature
Static pressure
mbar
kPa
≤ 57.5
≤ 5.75
Supply pressure (flow pres-
sure)
=
for natural gas E
mbar
kPa
17.4-25
1.74-2.5
=
for natural gas LL
mbar
kPa
17.4-25
1.74-2.5
=
for LPG
mbar
kPa
42.5-57.5
4.25-5.75
Tick gas type
Carbon dioxide content
CO
2
For natural gas
■ At lower heating output
% by vol.
7.5-9.5
■ At upper heating output
% by vol.
7.5-9.5
For LPG
■ At lower heating output
% by vol.
8.8-11.1
■ At upper heating output
% by vol.
8.8-11.1
Oxygen content O
2
■ At lower heating output
% by vol.
4.0-7.6
■ At upper heating output
% by vol.
4.0-7.6
Carbon monoxide content
CO
■ At lower heating output
ppm
< 1000
■ At upper heating output
ppm
< 1000
Commissioning/service reports
5585 174 GB