29
5784 566 - 10
Vitodens 100-W, B1HA series & B1KA Combi Technical Data
Venting
Two Pipe System
Two pipe system (room air independent) vertically vented
Vent system
diameter (in)
2*
3
4
Maximum
equivalent
length ft. (m)
98 (30)
164 (50)
200 (61)
Two pipe system (room air independent) horizontally vented
Two pipe system (room air independent) hybrid
*stainless steel is not available in 2 in.
Combustion air: CPVC, PVC, ABS and stainless steel
(field supplied)
Flue gas: CPVC and stainless steel (field supplied)
PP(s): (Viessmann supplied)
Vent system
diameter (in)
2*
3
4
Maximum
equivalent
length ft. (m)
98 (30)
164 (50)
200 (61)
Combustion air: CPVC, PVC, ABS and stainless steel
(field supplied)
Flue gas: CPVC and stainless steel (field supplied)
PP(s): (Viessmann supplied)
Vent system
diameter (in)
2*
3
4
Maximum
equivalent
length ft. (m)
98 (30)
164 (50)
200 (61)
Combustion air: CPVC, PVC, ABS and stainless steel
(field supplied)
Flue gas: CPVC and stainless steel (field supplied)
PP(s): (Viessmann supplied)
*stainless steel is not available in 2 in.
*stainless steel is not available in 2 in.
Intake
Flue
Intake
Flue
Flue
Intake