Vitodens 100-W, B1HA series & B1KA Combi Technical Data 

 

Product Information

General

Equipped with a Viessmann stainless steel heat exchanger 

for lasting performance and reliability and a modulating 

MatriX cylinder gas burner, the Vitodens 100-W wall-

mounted condensing boiler is the perfect combination of 

value, quality and Viessmann technology.

The benefits at a glance:

 Outstanding efficiency 

 

of 95.0% A.F.U.E. on all models.

 Lasting performance

 

with Viessmann-made SA240 / S43932 stainless steel  

 

Inox-Radial heat exchanger constructed to ASME  

 

Section IV and CSA B51.

 Low-emission

 

with fully-modulating stainless steel MatriX cylinder  

 

burner. Factory calibration eliminates adjustments in  

 the 

field.

 

< 45 ppm NOx (at 3% O

2

)

 Control variety 

 

Integrated boiler control interfaces with any level of  

 

external control - from room thermostat to outdoor  

 

reset and more.

  Compact, lightweight wall mount design  

 

and zero clearance to combustibles make it a great  

 

choice for limited-space installations.

  Extremely quiet operation

 

quieter than most refrigerators.

 

< 52 dBA [at 3.3 ft. (1 meter)] 

  Easy installation, service and maintenance

 

with all pipe connections located at the bottom 

 

and serviceable components (including electrical  

 

connections) easily accessible from the front.

 Multiple venting options

  -  Horizontal or vertical sealed combustion  

 

     coaxial, PP(s) vent system (Viessmann supplied).
  -  Horizontal, vertical or hybrid sealed combustion  

     double-pipe CPVC vent system (field supplied).
  -  Horizontal or vertical single pipe CPVC vent system 

     (field supplied).
  -  Horizontal or vertical single or double pipe PP(s), 

     flexible vent system (Viessmann supplied).

 Suitable for high altitude levels 

  of up to 10,000 ft. (3,000 m).

 Built-in automatic frost protection

  allows boiler to be shut off for an extended period 

  of time while protecting it against freeze-up.

 Reliable on demand domestic hot water (B1KA)

  - Plate type heat exchanger

  - Built-in diverting valve

  - Built-in Grundfos 3-speed pump

  - Built-in pressure bypass valve

  - Built-in water hammer arrester

  - Built-in flow sensor

  - Built-in temperature sensor

  - Supplied with a pressure relief valve rated at 150 psi

 Limited lifetime warranty

  in residential applications.

 

The B1KA boiler conforms to NSF/ANSI 372 for “lead  

  free” plumbing products as defined by applicable  

  US state laws and by section 1417 of the US Safe  

  Drinking Water Act.

Содержание Vitodens 100-W 125

Страница 1: ...put 21 to 125 MBH 6 2 to 36 6 kW Model Nos and pricing see Price List Gas Fired Wall Mounted Condensing Boiler with modulating stainless steel MatriX cylinder burner stainless steel Inox Radial heat e...

Страница 2: ...t 1 meter Easy installation service and maintenance with all pipe connections located at the bottom and serviceable components including electrical connections easily accessible from the front Multipl...

Страница 3: ...steel heat exchanger B Stainless steel MatriX cylinder burner C Burner blower D Gas and hydronic connections E Boiler control Standard Equipment Wall mount boiler and installation fittings c w 30 psi...

Страница 4: ...L 1 02 3 88 1 02 3 88 1 02 3 88 Boiler max flow rate 4 GPM L h 6 2 1400 6 2 1400 6 2 1400 Max operating pressure max allowable working pressure at 210 F 99 C psig bar 45 3 45 3 45 3 Boiler water temp...

Страница 5: ...m 2e 60 2e 60 2e 60 Combustion air supply coaxial connection 8 single outer in mm 4 100 2e 60 4 100 2e 60 4 100 2e 60 Noise level at 1 meter at full load at partial load dB dB 46 9 41 1 51 6 41 1 51 6...

Страница 6: ...i 150 Test pressure psi 300 Integrated pump flow rate DHW production 23 ft 9 8 m Head pressure Heating system operation with system side additional drop in pressure of max 6 ft of water 1 8 m USG min...

Страница 7: ...male thread E Combustion air opening for double pipe system F Combustion air opening for coaxial system G For B1HA series DHW tank heating supply For B1KA combi DHW H For B1HA series DHW tank heating...

Страница 8: ...W B1HA series and B1KA Legend A DHW tank heating supply for B1HA boilers DHW for B1KA boiler B DHW tank heating return for B1HA boilers DCW for B1KA boiler BWR Boiler water return BWS Boiler water su...

Страница 9: ...material or UL ULC listed CPVC gas vent material The zero inches vent clearance to combustibles for the Vitodens 100 W boiler supercedes the clearance to combustibles listing that appears on the speci...

Страница 10: ...or minimum flow rate of the Vitodens 100 W boiler An alternative method may be used such as primary secondary piping using closely spaced tees A low loss header offers additional benefits not provided...

Страница 11: ...max 130 W min 80 Built in pump Residual head Grundfos UPS15 78 three speed heating circuit DHW production pump for Vitodens 100 W B1HA 26 35 94 125 and B1KA 35 125 boilers in the factory setting the...

Страница 12: ...HW requirement for a single family house 0 Central DHW requirement for a multi family house Decentralized DHW requirement for a multi family house Number of draw points One draw point 0 Several draw p...

Страница 13: ...illustrates the changes in the outlet temperature subject to the flow rate at the tap If greater volume max flow rate through heat exchanger 3 7 GPM of water is required cold water needs to be mixed w...

Страница 14: ...technical information on DHW storage tanks see the Vitocell Technical Data Manual Mounting Vitodens 100 W boiler Installation Boiler mounting bracket and frame 1 Attach the wall mounting bracket supp...

Страница 15: ...of operation In some cases one granulate fill may last an entire year Contact Viessmann to order a neutralization unit for the Vitodens 100 W boiler See Viessmann Price List for order information The...

Страница 16: ...ature External heat demand OpenTherm OT or OT input module 0 10VDC accessory Viessmann outdoor temperature sensor OTS field wiring OpenTherm OT field wiring Instantaneous DHW control B1KA The control...

Страница 17: ...flow rate of your application Legend Vprimary Boiler circuit flow rate Vsecondary Heating circuit flow rate Vbypass Bypass flow rate Qprimary Heat supplied by boiler Qsecondary Heat consumed by system...

Страница 18: ...iessmann NTC 10K ohms 77 F 25 C Outdoor Temperature Sensor OTS Sensor location North or northwest wall of building 80 to 100 in 2 to 2 5 m above ground or in case of a multi storey building approximat...

Страница 19: ...a forced draft design The benefits of forced draft systems are lower component temperatures direct air fuel connection premix for improved mixing and longer service life of the boiler due to mild to m...

Страница 20: ...se of a low loss header is recommended if the water flow rate is less than 1 7 GPM 400 L h or more than 6 2 GPM 1400 L h The low loss header is available as accessory part Maximum Flow Rates Ensure th...

Страница 21: ...is available as accessory part DHW supply and return piping between boiler DHW connections and the Viessmann DHW tank connections shall be a minimum of 1 in nominal pipe diameter irrespective of the...

Страница 22: ...than 1 7 GPM 400 L h or more than 6 2 GPM 1400 L h The low loss header is available as an accessory part DHW supply and return piping between boiler DHW connections and the Viessmann DHW tank connecti...

Страница 23: ...al head for the heating system side is 4 3 ft of water column at the boiler maximum flow rate of 6 2 GPM System Layout 4 Model B1KA 35 125 Output MBH 117 t 30 F 17 C rise GPM L h 7 8 1772 35 F 19 5 C...

Страница 24: ...F 17 C rise GPM L h 7 8 1772 35 F 19 5 C rise GPM L h 6 7 1522 40 F 22 C rise GPM L h 5 9 1328 Requires low loss header or closely spaced tees Legend AV Air vent PRV Pressure relief valve boiler DPRV...

Страница 25: ...1328 Requires low loss header or closely spaced tees Legend AV Air vent PRV Pressure relief valve boiler DPRV Pressure relief valve DHW 150 psi WSE Water softener equipment DHW Domestic hot water DCW...

Страница 26: ...cut off The Vitodens 100 boiler is certified with an internal flow switch sensor however a low water cut off may be required by local jurisdiction If required an approved type low water cut off devic...

Страница 27: ...ifreeze content is 50 for the B1HA 26 35 94 125 and 30 for the B1KA 35 125 Do not use antifreeze other than specifically made for hot water heating systems The system may also contain components which...

Страница 28: ...00 80 125 100 150 Maximum equivalent length ft m 82 25 98 30 118 36 Coaxial horizontally vented PP s Viessmann supplied Vent system diameter mm 60 100 80 125 100 150 Maximum equivalent length ft m 82...

Страница 29: ...ied Flue gas CPVC and stainless steel field supplied PP s Viessmann supplied Vent system diameter in 2 3 4 Maximum equivalent length ft m 98 30 164 50 200 61 Combustion air CPVC PVC ABS and stainless...

Страница 30: ...ft m 86 20 164 50 200 61 CPVC and stainless steel field supplied PP s Viessmann supplied Single pipe system room air dependant vertically vented Vent system diameter in 2 3 4 Maximum equivalent length...

Страница 31: ...er in 80 flex 2 in comb 80 100 Maximum equivalent length ft m 65 20 123 37 150 46 Combustion air CPVC PVC ABS and stainless steel field supplied Flue gas PP s Viessmann supplied Flexible single pipe s...

Страница 32: ...F 40 40 35 31 25 13 20 4 18 0 16 3 14 7 12 10 10 14 9 16 8 18 7 19 6 21 5 23 4 25 3 27 2 28 1 30 0 32 1 34 2 36 3 37 4 39 5 41 6 43 7 45 8 46 9 48 10 50 12 54 14 57 16 61 18 64 20 68 25 77 30 86 35 95...

Отзывы: