Functions when operating with Vitodata 100:
For all heating circuits in a heating system:
■
Remote monitoring
:
– Forwarding messages via email to terminal devices using the
email client function.
– Forwarding messages via SMS to mobile phone/smartphone or
fax (via chargeable internet service Vitodata 100 fault manage-
ment).
■
Telecontrol
:
Selecting operating programs, set values, time programs and heat-
ing curves.
Note
For further information, see www.vitodata.info.
Configuration:
Configuration takes place automatically.
If the DHCP service is enabled, no further adjustments on the DSL
router are required.
Standard delivery:
■ Vitocom 100, type LAN1 with LAN socket.
■ With or without LON communication module for fitting into the
Vitotronic control unit.
■ Connecting cables for LAN and communication module.
■ Power cable with plug-in power supply unit.
■ Vitodata 100 fault management for 3 years.
On-site requirements:
■ The communication module must be installed in the control unit.
■ Before commissioning, check the system requirements for commu-
nication via the IP networks (LAN).
■ Internet connection with flat rate data (
without
time or volume limits).
■ DSL router with dynamic IP address (DHCP).
Note
For information on registering and using the Vitotrol app and
Vitodata 100, see www.vitodata.info.
Specification
160
34
111
Power supply via plug-in power sup-
ply unit
230 V~/5 V–
Rated current
250 mA
Power consumption
8 W
Safety category
II
IP rating
IP 30 to EN 60529, ensure
through design/installation
Permissible ambient temperature
– During operation
0 to +55 °C
Installation in living spaces or
boiler rooms (standard ambi-
ent conditions)
– During storage and transport
–20 to +85 °C
Vitocom 100, type GSM2
For part no., see the current pricelist
For remote monitoring and remote control of a heating system via
mobile phone networks.
For the transmission of messages and settings for operating programs
by means of SMS.
Storage combi boiler.
Functions:
■ Remote monitoring via SMS to 1 or 2 mobile phones
■ Remote monitoring of additional systems via digital input (floating
contact)
■ Remote setup with mobile phone via SMS
■ Operation with mobile phone via SMS
Note
For further information, see www.vitocom.info.
Configuration:
Mobile phones via SMS
Standard delivery:
■ Vitocom 100 with integral mobile phone modem.
■ Connecting cable with Rast 5 system connectors for connection to
the control unit KM BUS.
■ Mobile aerial (3.0 m long), magnetic base and adhesive pad.
■ Power cable with plug-in power supply unit (2.0 m long).
On-site requirements:
■ Good reception for GSM communication with the selected mobile
phone operator.
■ Total length of all KM BUS subscriber cables up to 50 m.
Control units
(cont.)
Gas condensing boilers
VIESMANN
81
5822 449 GB
9