![Viessmann VITOCONNECT OPTO2 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/viessmann/vitoconnect-opto2/vitoconnect-opto2_operating-instructions-manual_1017700019.webp)
19
Interpreting the LED indicators
LED
–
operating status
Illuminates white.
Vitoconnect successfully connected to the heat generator and Viessmann server.
Only in conjunction with Vitoconnect, type OT2
Pulsates white.
"Comfort mode" is on.
LED
–
communication with the WiFi and Viessmann server
Flashes green.
Establishing connection between Vitoconnect and Viessmann server
Illuminates green.
■
Starting Vitoconnect.
Or
■
Access point mode is active.
Pulses yellow.
Could not connect Vitoconnect to WiFi router: See page 23.
Illuminates yellow.
No connection to the internet: See page 23.
Illuminates red.
Could not connect Vitoconnect to Viessmann server: See page 23.
LED
–
system functions and communication with heat generator
Illuminates green.
■
Starting Vitoconnect.
Or
■
Installing new software.
!
Please note
Take care not to damage the Vitoconnect.
Never
disconnect the Vitoconnect from the power supply during software
installation.
Only in conjunction with Vitoconnect, type OT2
Flashes yellow.
Communication error with Vitotrol 100, type OT1: See page 23.
Flashes yellow quickly.
No connection to the heat generator: See page 23.
Flashes red.
Vitoconnect is ready to be reset to the factory settings: See page 24.
Illuminates red.
Fault on the control unit of the heat generator: See page 23.
LEDs
and
–
software or hardware fault
Flashing red quickly.
Software or hardware fault: See page 23.
Note
Pulses slowly:
The LED illuminates once every
4 seconds brightly and more dimly.
Pulsing:
The LED illuminates once every sec-
ond brightly and more dimly.
Flashing:
The LED comes on once per second.
Flashing rapidly: The LED comes on twice per sec-
ond.
Checking the network settings
Have the following settings on the WiFi router
checked, and if necessary adjusted, by an IT expert:
■
Dynamic IP addressing must be set.
■
Port 80, port 123, port 443 and port 8883 must be
enabled for outgoing connections.
Registering the user and setting up the heating system
1.
Download the ViCare app from the App Store or
Google Play Store and install it.
2.
Start the ViCare app and tap on
"Create
Account"
.
Commissioning
Display and controls
(cont.)