11
Vitotrol 100, type OT1
Installation type: Wall mounting
■
On an internal wall in the main living room, approx.
1.5 m above the floor
■
The installation location must be dry and free of frost.
■
Ensure ambient temperatures between 0 and
+40 °C.
■
Not next to windows or doors
■
Not above radiators
■
Not between shelves, in recesses, etc.
■
Not near heat sources (direct insolation, fireplace,
TV set, etc.)
Ranges
The range of WiFi connections may be reduced by
walls, ceilings and interior fixtures. These weaken the
WiFi signal and can cause poor reception.
Range reduction:
■
On their way between transmitter and receiver, WiFi
signals are
damped
, e.g. by air or when penetrating
walls.
■
WiFi signals are
reflected
by metallic objects, e.g.
reinforcements in walls, metal foil of thermal insula-
tion and thermal glazing with metallised thermal
vapour deposit.
■
WiFi signals are
isolated
by service ducts and lift
shafts.
■
WiFi signals are
disrupted
by devices that also
operate with high frequency signals. Maintain a dis-
tance of
at least 2 m
from these devices:
–
Computers
–
Audio and video systems
–
Radio signals
–
Electronic transformers
–
Pre-ballasts
Note
To ensure a good WiFi connection, we recommend
keeping the distance between the Vitoconnect and the
WiFi router as short as possible.
Preparing for installation