6
5813 312 - 01
Vitocell 300-W/V, EVIA/EVIB Installation, Operating and Service
About These Instructions
Product Information
Take note of all symbols and notations intended to draw attention to potential hazards or important product information.
These include “WARNING”, “CAUTION”, and “IMPORTANT”. See below.
Warnings draw your attention to the presence of
potential hazards or important product information.
Cautions draw your attention to the presence of
potential hazards or important product information.
Helpful hints for installation, operation or maintenance
which pertain to the product.
This symbol indicates that additional, pertinent
information is to be found.
This symbol indicates that other instructions must be
referenced.
WARNING
Indicates an imminently hazardous situation which, if
not avoided, could result in substantial product/property
damage, serious injury or loss of life.
CAUTION
Indicates an imminently hazardous situation which, if not
avoided, may result in minor injury or product/property
damage.
IMPORTANT
Vitocell 300-W, EVIA 42 USG (160 L) capacity
Vitocell 300-V, EVIA 53 USG (200 L) capacity
Vitocell 300-V, EVIA 79 USG (300 L) capacity
Vitocell 300-V, EVIB 119 USG (450 L) capacity
Indirect-fired domestic hot water storage tank with one
heat exchanger coil for use with hot water heating boilers,
residential/commercial heating plants, and low-temperature
heating systems.
This tank version is not suitable for steam heating
applications.
General Information
- Position tank carefully and remove packaging.
- Leave adequate clearance to the wall or other objects
enabling easy access to the pressure relief valve.
- Install tank(s) on flooring or foundation capable of
supporting the weight of the tank(s) filled with water.
Recommended service clearances
Rear
in. (mm)
18 (460)
Sides
May be reduced if rear pipe connections can
be reached with less clearance
in. (mm)
12 (300)
Top
in. (mm)
12 (300)
Front
in. (mm)
29 (730)
Minimum clearances to combustibles
All sides
in. (mm)
0 (0)
Floor
combustible
CAUTION
Install the DHW tank in a frost-protected and draft-free
room. Otherwise it must be drained when not in use, in
order to reduce the risk of damages caused by freezing.