Connections
9
DHW Tank Installation (42 to 79 USG / 160 to 300 ltr)
DHW temperature sensor installation
1.
Mount sensor on the outside of the
sensor spring-clip (not in the center
groove) so that it is flush with the
front of the sensor spring-clip.
2.
Snap sensor cabling into plastic clip
of sensor mounting equipment.
3.
Completely insert sensor mounting
hardware along with sensor into
sensor well.
4.
Remove top panel and insulation
blanket.
5.
Remove cap from thermometer
opening.
6.
Slide thermometer sensor cable
through thermometer opening in the
panel and insert thermometer.
7.
Completely insert sensor into metal
clip on flange.
8.
For applications with Vitotronic 100
control, use supplied plastic clip and
two screws to secure Honeywell bulb
capillary. For applications with the
Vitotronic 200 or 300 control option,
use supplied plastic clip and two
screws to secure sensor cable
to
the tank sheet metal.
9.
For Solar Domestic Hot Water with
Vitosolic 200, SCU124 or SCU 224,
use supplied plastic clip and two
screws to secure sensor cable
to
the tank sheet metal.
4.
5.
6.
3.
2.
1.
7.
Fig 6.
Sensor installation
5
1
6
7
5
1
9
v
2
.2
Never wrap sensor with any type of
tape or insulation.
CAUTION