Connections
12
DHW Tank Installation (120 USG / 450 ltr)
Installation of thermal insulation
1.
Slide bottom thermal insulation
blanket underneath the DHW tank (if
not already installed).
2.
Push thermal insulation jacket at the
front onto the flange and sensor well.
3.
Hook enclosure strips of the thermal
insulation jacket into each other.
4.
Guide the thermometer sensor cable
through the opening provided and
push in the thermometer.
5.
Insert the sensor until it bottoms out
inside sensor well, and secure with
the spring clip.
6.
Push insulation plugs into the
appropriate openings as shown.
1.
Fig 10.
4.
3.
6.
2.
5.
Fig 11.
Installation of thermal
insulation
5
1
6
7
5
1
9
v
2
.2
The thermal insulation must not come
into contact with open flames.
Exercise caution when welding and
soldering in the vicinty of the tank.
CAUTION