Viessmann 5443202
13
|
SCU124
Legend:
Symbol
Specification
x
Channel is available
x*
Channel is available if the corresponding option is activated.
s
Channel is specifically available in this system layout
Adjustment Channels
Channel
Description
Factory setting
Page
Arr
x
System
3
20
DT O
x
Switch-on temperature difference
12.0 °Ra [6.0 K]
20
DT F
x
Switch-off temperature difference
8.0 °Ra [4.0 K]
20
DT S
x
Nominal temperature difference
20.0 °Ra [10.0 K]
20
RIS
x
Rise control R1
4 °Ra [2 K]
20
nMN
x
Minimum pump speed
30 %
20
S MX
x
Maximum tank temperature
140 °F [60 °C]
21
EM
x
Emergency temperature collector
270 °F [130 °C]
21
CMX
s
Maximum collector temperature
230 °F [110 °C]
22
OCN
x
Option minimum limitation
OFF
23
CMN
x*
Minimum collector temperature
50 °F [10 °C]
23
OCF
x
Option antifreeze
OFF
23
CFR
x*
Antifreeze temperature
40.0 °F [4.0 °C]
23
O TC
x
Option tube collector
OFF
24
TCST
x*
OTC starting time
07:00
24
TCEN
x*
OTC ending time
19:00
24
TCRU
x*
OTC runtime
30 s
24
TCIN
x*
OTC standstill interval
30 min
24
OHQM
x
Option energy metering
OFF
24
FMAX
x*
Maximum flow
6.0 l
24
MEDT
x*
Antifreeze type
1
24
MED%
x*
Antifreeze concentration (only if MEDT = propylene or ethylene)
45 %
24
MAN1
x
Manual operation R1
Auto
26
MAN2
x
Manual operation R2
Auto
26
LANG
x
Language
En
26
UNIT
x
Temperature unit
°C
26
RESE
x
Reset - back to factory defaults
26
W0040100
Version number
Содержание SCU124