![Viessmann PV1 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/viessmann/pv1/pv1_service-instructions-for-contractors_1016907008.webp)
8
Note
On gas burners, disconnect the gas supply pipe.
4x
Fig. 1
Cleaning the turbulators, heating surface, flue outlet and flue pipe
C
B
A
Fig. 2
1.
Remove turbulators
A
without applying force.
2.
Clean flues
B
and combustion chamber
C
with
the brush.
Remove combustion residues with a vacuum
cleaner.
D
Fig. 3
3.
Use a vacuum cleaner to remove combustion resi-
dues from the flue and the flue outlet through
cleaning aperture
D
in the flue outlet.
Commissioning, inspection, maintenance
Opening the boiler door and cleaning cover
5692701
Содержание PV1
Страница 14: ...14 Commissioning inspection maintenance Operating and service documents cont 5692701 ...
Страница 30: ...30 5692701 ...