Safety, Installation and Warranty Requirements

Please ensure that this manual is read and understood before commencing installation. Failure to comply

with the issues listed below

and details printed in this manual can cause

product/property damage

, and/or

severe personal injury

. Ensure all requirements below are

understood and fulfilled (including detailed information found in manual subsections).

H

Licensed professional heating
contractor

The installation, adjustment, service, and
maintenance of this equipment

must be

performed by a licensed professional
heating contractor.

"

Please see sections

entitled “Safety” and
“Important Installation
Requirements.”

H

Product documentation

Read all applicable documentation

before

commencing installation. Store
documentation near boiler in a readily
accessible location for reference in the
future by service personnel.

"

For a listing of applicable

literature, please see
section entitled “Important
Installation Requirements.”

H

Advice to owner

Once the installation work is complete, the
heating contractor must familiarize the
system operator/ultimate owner with all
equipment, as well as safety precautions/
requirements, shut-down procedure, and
the need for professional service annually
before the heating season begins.

H

Warranty

Information contained in this and related
product documentation must be read and
followed.

Failure to do so renders warranty

null and void.

Safety Terminology

The following terms are used throughout this manual to bring attention to the presence of potential hazards or important product information.

Please heed the advice given!

Helpful hints for installation, operation or
maintenance which pertain to the
product.

5167

137

Indicates an imminently hazardous
situation which, if not avoided, will
result in death, serious injury or
substantial product/property
damage.

DANGER

Indicates an imminently hazardous
situation which, if not avoided, could
result in death, serious injury or
substantial product/property
damage.

WARNING

Indicates an imminently hazardous
situation which, if not avoided, may
result in minor injury or
product/property damage.

CAUTION

IMPORTANT

Содержание Dekamatik-HK1

Страница 1: ...tallation Instructions Dekamatik HK1 Digital indoor outdoor heating circuit control unit for mounting on the mixing valve Part No 7450 107 for wall mounting Part No 7450 110 Please file in Service Bin...

Страница 2: ...s H Advice to owner Once the installation work is complete the heating contractor must familiarize the system operator ultimate owner with all equipment as well as safety precautions requirements shut...

Страница 3: ...on Dekamatik HK1 for Mounting on the Mixing Valve 8 Dekamatik HK1 for Wall Mounting 9 Electrical Connections Overview 10 Sensors 12 Supply temperature sensor 12 Outdoor temperature sensor 13 Accessori...

Страница 4: ...nstall power supply in accordance with the regulations of the authorities having jurisdiction or in the absence of such requirements in accordance with National Codes Viessmann recommends the installa...

Страница 5: ...igital indoor outdoor heating circuit control unit for one heating circuit with mixing valve either with drive module for mounting on Viessmann mixing valve or for wall mounting and connection of a se...

Страница 6: ...iessmann 2 wire BUS for communication with other Dekamatik control units External heat demand external heat disable 1It is possible to connect a separate room temperature sensor accessory instead of t...

Страница 7: ...Heating circuit pump Power supply Remote control 2 Viessmann 2 wire BUS for communication with other Dekamatik control units External heat demand external heat disable 1It is possible to connect a sep...

Страница 8: ...ending on size of mixing valve onto the threaded bolts of the mixing valve 2 Place the base plate in position and screw on with the washers and nuts provided 3 Snap the control unit with drive module...

Страница 9: ...the wall with three screws 3 Carry out the electrical connections i e mixing valve motor and compiled fault indication see page 18 and 19 4 Pull off the cover 5 Push the control unit in the guideways...

Страница 10: ...ltage connections X14 for outdoor temperature sensor or room temperature sensor accessory supply temperature sensor X3 not used or X3 for return temperature sensor accessory in conjunction with underf...

Страница 11: ...1 Overview continued Wall mounting fixture Terminal strips for connection of mixing valve motor or compiled fault indication 5167 137 Fig 4 Electrical connections in the wall mounting fixture Dekamati...

Страница 12: ...right 2 Open the case of the sensor with a screwdriver 3 Place the perforated mounting strap supplied inside the sensor case on the tensioning screw run it around the supply pipe and place back on the...

Страница 13: ...f the heating circuit controls the south facing part of the building the outdoor temperature sensor must be mounted on the south facing wall Ensure that the outdoor temperature sensor is not located o...

Страница 14: ...elief clamp 4 Insert connector in socket X 14 in the terminal compartment see page 10 install strain relief clamp Wall mounting fixture for using the programming unit as a remote control The programmi...

Страница 15: ...10 install strain relief clamp 8 Insert the programming unit in the wall mounting fixture WS remote control unit RS remote control unit Remote control unit 1 Mount the remote control unit in accordan...

Страница 16: ...t the 3 wire cable from the heating circuit pump to connector 3 Insert connector in the socket for the heating circuit pump 5167 137 In the case of underfloor heating systems a high limit aquastat imm...

Страница 17: ...wire according to the rating of the pump to be connected 3 Connect the heating circuit pump to the contactor 3 Phase pumps require use of contactors with overload protection 4 Connect contactor to con...

Страница 18: ...reak open the cable bushing install strain relief clamp 3 Insert connector in socket X 11 in the terminal compartment see page 10 install strain relief clamp External heat demand or external changeove...

Страница 19: ...oiler control unit a compiled fault message is also relayed to these via the Viessmann 2 wire BUS accessory Wall mounting fixture 1 Select the signal device provided by the customer Rated voltage AC 1...

Страница 20: ...nce with the regulations of the authorities having jurisdiction or in the absence of such requirements in accordance with National Codes The Dekamatik HK 1 is standard equipped with a 120 V power cord...

Страница 21: ...ng valve motor is properly connected j Ensure correct rotational direction of mixing valve motor and if necessary change in accordance with the Service Instructions j Ensure heating circuit pump is pr...

Страница 22: ...s II Degree of protection IP 22 D to EN 60529 Ambient temperature during operation 32 to 104 F 0 to 40 C during storage and transport 4 to 104 F 20 to 65 C Dead zone of PI controller for mixing valve...

Страница 23: ...Appendix 23 Notes 5167 137...

Страница 24: ...iessmann ca mail viessmann ca Viessmann Manufacturing Company U S Inc 45 Access Road Warwick Rhode Island 02886 USA Tel 401 732 0667 Fax 401 732 0590 www viessmann us com mail viessmann us com 24 5167...

Отзывы: