Vitodens 200-W B2HA/B2HB, 222-F B2TA/B2TB Operating

5461 885 - 04

Safety

Safety, Installation and Warranty Requirements

2

Please ensure that these instructions are read and understood before commencing installation. Failure to comply with 

the instructions listed below and details printed in this manual can cause product/property damage, severe personal 

injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information 

found in manual subsections).

WARNING

Installers must follow local regulations with respect to 

installation of carbon monoxide detectors. Follow the 

Viessmann maintenance schedule of the boiler contained

in this manual.

  

Product documentation

 

Read all applicable documentation before commencing  

 

installation. Store documentation near boiler in a 

     readily accessible location for reference in the future  

 

by service personnel.

 

For a listing of applicable literature,

     please see section entitled “Important

     Regulatory and Safety Requirements”.

  

Warranty

     Information contained in this and 

 

related product documentation must 

 

be read and followed. Failure to do 

 

so renders the warranty null and void.

  

Licensed professional heating contractor

     The installation, adjustment, service and maintenance  

 

of this equipment must be performed by a licensed

   professional heating contractor.

 

Please see section entitled 

 

“Important Regulatory and Installation 

 Requirements”.

 

Contaminated air

   Air contaminated by chemicals can cause by-products  

 

in the combustion process, which are poisonous to 

 

inhabitants and destructive to 

 Viessmann 

equipment.

 

For a listing of chemicals which 

 

cannot be stored in or near the

     boiler room, please see subsection 

 

entitled “Mechanical room” in the 

 “Installation 

Instructions”.

  

Advice to owner

     Once the installation work is complete, the heating  

 

contractor must familiarize the system operator/ 

 

ultimate owner with all equipment, as well as safety  

 

precautions/requirements, shutdown procedure, and  

 

the need for professional service annually before the

     heating season begins.

  

Carbon monoxide

     Improper installation, adjustment, service and/or  

 

maintenance can cause flue products to flow into 

 

living space. Flue products contain poisonous carbon  

 monoxide 

gas.

 

For information pertaining to the 

 

proper installation, adjustment, service 

 

and maintenance of this equipment to 

 

avoid formation of carbon  monoxide, 

 

please see subsection entitled 

 

“Mechanical room” and “Venting 

 

requirements” in the “Installation Instructions”.

 

Fresh air

  

This equipment requires fresh air for 

 

safe operation and must be installed 

 

ensuring provisions for adequate 

 

combustion and ventilation air exist.

 

For information pertaining to the 

 

fresh air requirements of this product, 

 

please see subsection entitled 

 

“Mechanical room” in the “Installation 

 Instructions”.

 Equipment venting

 

Never operate boiler without an installed venting  

 

system. An improper venting system can cause 

 

carbon monoxide poisoning.

 

For information pertaining to 

 venting 

and chimney requirements, 

 

please see section entitled “Venting 

 Connection”. 

All products of 

 

combustion must be safely vented 

 

to the outdoors.

Operating and Service Documentation

It is recommended that all product documentation such as 

parts lists, operating and service instructions be handed 

over to the system user for storage. Documentation is to 

be stored near boiler in a readily accessible location for 

reference by service personnel.

WARNING

This boiler requires fresh air for safe operation and must 

be installed with provisions for adequate combustion 

and ventilation air (in accordance with local codes and 

regulations of authorities having jurisdiction).
Do not operate this boiler in areas with contaminated 

combustion air. High levels of contaminants such as 

dust, lint or chemicals can be found at construction 

sites, home renovations, in garages, workshops, in dry 

cleaning/laundry facilities, near swimming pools and in 

manufacturing facilities.
Contaminated combustion air will damage the boiler 

and may lead to substantial property damage, severe 

personal injury and/or loss of life. Ensure boiler/burner is 

inspected and serviced by a qualified heating contractor 

at least once a year in accordance with the Service 

Instructions of the boiler.

Содержание B2HAA95

Страница 1: ...d installer service agency or the gas supplier If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment and or operation could cause carbon monoxide poisoning resulting in injury or loss of life This product must be installed and serviced by a professional service techni...

Страница 2: ...before the heating season begins Carbon monoxide Improper installation adjustment service and or maintenance can cause flue products to flow into living space Flue products contain poisonous carbon monoxide gas For information pertaining to the proper installation adjustment service and maintenance of this equipment to avoid formation of carbon monoxide please see subsection entitled Mechanical ro...

Страница 3: ...summertime changeover 8 Overview of Controls 9 On Board Vitotronic 200 HO1B Control 9 Modular structure 9 Programming unit HO1B 9 Menu 10 Programming unit 10 Help menu 10 Standard menu 10 Symbols on the display 11 Extended menu 11 How to Use the Controls 12 Zone Circuit Steps 14 Starting the Heating System 15 Shutting Down the Heating System 15 Required Settings Central Heating 16 Selecting a Heat...

Страница 4: ...ation 30 Scanning Service Messages 31 Scanning Fault Messages 32 Emissions Test Mode 33 Rooms are too Cold 34 Rooms are too Hot 34 There is no Hot Water 35 The DHW is too Hot 35 Flashes and Fault is Displayed 35 Flashes and Service is Displayed 36 Controls Locked Out is Displayed 36 External Hook up is Displayed 36 External Program is Displayed 36 Inspection Cleaning Maintenance 37 Menu Overview 3...

Страница 5: ...ontractor should always perform the initial start up and explain the system Any warranty is null and void if these instructions are not followed Working on the equipment All personnel working on the equipment or the heating system must have the proper qualifications and hold all necessary licenses Ensure main power to equipment heating system and all external controls has been deactivated Close ma...

Страница 6: ...tructing the flow of combustion and ventilation air and no chemicals garbage gasoline combustible materials flammable vapors and liquids are stored not even temporarily in the vicinity of the boiler Do not allow unsupervised children near the boiler Service inspection of the boiler and the system is recommended once a year Maintenance service and cleaning are specified in the Installation Instruct...

Страница 7: ...e and wear parts Components which are not tested with the heating system may damage the heating system or affect its functions Installation or replacement may only be performed by a qualified heating contractor IMPORTANT Installation area conditions Ensure ambient temperatures are higher than 32 F 0 C and lower than 104 F 40 C Prevent the air from becoming contaminated by halogenated hydrocarbons ...

Страница 8: ...ased on your personal preference of up to 140ºF 60ºC The domestic hot water recirculation pump if installed ensures that domestic hot water is readily available when domestic hot water is drawn 2 Domestic hot water heating can be set not to take place for the times you spend sleeping for example General Information Your System is Preset at the Factory The control unit is factory set to Heating and...

Страница 9: ...splay with graphic ability Large font and black white depiction for good contrast Context sensitive help text Removable programming unit can be mounted on the wall with separate accessory With digital time switch Control keys for Navigation Confirmation Help and additional information Menu Setting the Room temperature Reduced room temperature DHW temperature Heating program Time programs for centr...

Страница 10: ...is shown see the following chapter Press Refer to the remote control operating instructions You can change any settings on your heating system centrally at the programming unit of the control unit If remote controls are installed in your rooms you can also adjust the settings at the remote controls There are two control levels available the Standard menu and the Extended menu Standard menu heating...

Страница 11: ...you are somewhere in the menu Keep pressing until the standard menu appears Note 2 minutes after any setting has been made the display automatically reverts to the standard menu Extended menu In the extended menu you can adjust and scan the settings from the control unit s range of functions used less frequently e g time programs and holiday programs The menu overview can be found on page 38 Call ...

Страница 12: ...educed 1 Press OK This takes you to the standard menu see page 10 2 Press This takes you to the extended menu see page 11 The selected menu option is highlighted in white The dialogue line E see diagram on page 11 then shows the necessary instructions The following diagram shows how to make settings with different dialogue lines using the set room temperature setting as an example Legend B Current...

Страница 13: ...13 5461 885 04Vitodens 200 W B2HA B2HB 222 F B2TA B2TB Operating Controls How to Use the Controls continued ...

Страница 14: ...Vitodens 200 W B2HA B2HB 222 F B2TA B2TB Operating 5461 885 04 14 Zone Circuits Steps Controls ...

Страница 15: ...o DHW heating H Frost protection for the boiler and the DHW tank is enabled For the heating circuit displayed in the header Standard menu 1 for the heating program Standby mode frost protection monitoring 2 OK to confirm For the other heating circuits Extended menu 1 2 Heating 3 Select the heating circuit if necessary see page 16 4 Heating program 5 Standby mode frost protection monitoring Note Th...

Страница 16: ...e header will again display HC1 see page 10 For changes to the heating circuit display in the standard menu see page 29 Heating The heating of all rooms can if necessary be split over several heating circuits H In the case of heating systems with several heating circuits for all central heating settings first select the heating circuit where you want to make a change H This selection is not possib...

Страница 17: ...ating circuit if necessary see page 16 4 Set reduced room temp 5 Set the required value The rooms are heated to this temperature H Between the time phases for standard heating mode see page 18 H In the holiday program see page 21 Factory setting Heating and DHW For the heating circuit displayed in the header Proceed as described on page 11 For the other heating circuits Extended menu 1 2 Heating 3...

Страница 18: ...the extended menu you can scan the current time program under Information see chapter Scanning information Heating circuit group Extended menu 1 2 Heating 3 Select the heating circuit if necessary 4 Heating time program 5 Select part of the week or a day 6 Select the time phase or 7 Set the start and end points for the relevant time phase 8 Press to exit the menu Note If you want to terminate a ti...

Страница 19: ...ve slope and level are displayed by pressing 6 Set the required value Example Change the heating curve slope to 1 5 A graph clearly shows the change in the heating curve as soon as you alter the value for the slope or level Depending on various outside temperatures shown on the horizontal axis the assigned set flow temperatures for the heating circuit are highlighted white Stopping the Central Hea...

Страница 20: ...16 4 Party mode 5 Set the required room temperature during party mode Display in the standard menu H The rooms are heated to the required temperature H DHW is reheated to the selected set temperature Ending the comfort function H Automatically after 8 hours or H Automatically when the system switches to standard heating mode in accordance with the time program or H In the extended menu set Party m...

Страница 21: ...ant to make changes contact your local heating contractor Depending on the heating program selected the holiday program can have various effects H Heating program Heating and DHW The rooms are heated to the selected reduced room temperature see page 17 DHW heating is switched OFF H Heating program Only DHW For all heating circuits frost protection monitoring is only enabled for the boiler and the ...

Страница 22: ...heating below H Have you set the required time program For settings see page 23 Extended menu 1 2 DHW 3 Set DHW temperature 4 Set the required value Note The control unit is set so that DHW heating applies to all heating circuits If you want to make changes contact your local heating contractor Extended menu 1 2 Heating 3 Select the heating circuit if necessary see page 16 4 Heating program 5 Heat...

Страница 23: ...week or different Set the start and end points for each time phase H When setting bear in mind that your heating system requires some time to heat the DHW to the required temperature H In the Extended menu you can scan the current time program under Information see chapter Scanning information DHW group Extended menu 1 2 DHW 3 DHW time prog 4 Individual 5 Select part of the week or a day 6 Select ...

Страница 24: ... page 40 H Automatic mode is set for the DHW circulation pump time program In other words the DHW circulation pump operates in parallel to the DHW heating time program H If you don t want the automatic mode you can select up to 4 individual time phases per day for the DHW circulation pump which can be the same for every day of the week or different Set the start and end points for each time phase ...

Страница 25: ...ms For the heating circuit displayed in the header Standard menu 1 for the heating program Standby mode frost protection monitoring 2 OK to confirm For the other heating circuits Extended menu 1 2 Select the heating circuit if necessary see page 16 3 Heating 4 Heating program 5 Standby mode frost protection monitoring You do not want DHW but do want to heat the rooms Extended menu 1 2 Select the h...

Страница 26: ...r the slope or shift Depending on various outside temperatures shown on the horizontal axis the assigned set supply temperatures for the heating circuit are highlighted in white Your system s heating characteristics are affected by the slope and the shift of the selected heating curve Further information about the heating curve can be found under Terminology on page 40 Setting the heating curve Fa...

Страница 27: ...ettings 3 Brightness 4 Control or Screen saver 5 Set the required brightness You can give heating circuits 1 2 and 3 HC1 HC2 and HC3 individual names The abbreviations HC1 HC2 and HC3 will be retained Extended menu 1 2 Settings 3 Name for heating circ 4 Heating circuit 1 Heating circuit 2 or Heating circuit 3 5 Change 6 You can select the required symbol with 7 takes you to the next character 8 Pr...

Страница 28: ... Set the time and date Note The entered term is deleted with Reset Heating circuit 1 will then be shown again Example Name for Heating circuit 2 Apartment The menu shows Apartment for Heating circuit 2 Setting the Time and Date Setting the Language At the commissioning stage the display is in German 1 Sprache Language Deutsch DE German 2 Select the required language with 3 Accept by pressing OK To...

Страница 29: ... menu 1 2 Settings 3 Standard setting 4 Heating circuit 1 Heating circuit 2 or Heating circuit 3 The following settings and values are reset H Set room temperature for standard heating mode Set room temperature H Set room temperature for reduced heating mode Set red room temp H Heating program Heating program H Set DHW temperature Set DHW temperature H Time program for central heating Heating time...

Страница 30: ...tended menu Extended menu 1 2 Information 3 Select the category 4 Select the required scan Scanning in conjunction with solar thermal systems Extended menu 1 2 Solar energy The solar energy yield for the past 7 days is displayed on a graph The flashing line on the graph indicates that the current day is not yet over Note Further scanning options e g for the solar circuit pump hours run can be foun...

Страница 31: ...calls up information on the service that is due 3 If you want to acknowledge the service message follow the instructions in the menu Contact your local heating contractor The service message is transferred to the menu Display in the standard menu Display in the extended menu Note If the service can only be carried out at a later date the service message is displayed again the following Monday Call...

Страница 32: ...code next to it on the right In this example Outside temp sensor 18 and Fault A2 This enables the heating contractor to be better prepared for the service call and may save additional travelling costs 4 If you want to acknowledge the fault message follow the instructions in the menu The fault message is transferred to the menu Display in the standard menu Note If you have connected up signalling e...

Страница 33: ...y be activated by a certified technician during the annual inspection Extended menu 1 2 Test mode 3 Flue gas test ON If the burner is on the symbol is shown Note You can also enable emissions test mode if the controls are locked out by your heating contractor Ending emissions test mode H Automatically after 30 min H Press OK ...

Страница 34: ...eserves and re order if required With natural gas Open the gas shut off valve If necessary check with your gas supply utility Combustion controller is shown on the display Press R reset button see page 15 Acknowledge the fault see page 32 Notify your heating contractor if this fault recurs The fault message is displayed until the cause is rectified Fault is displayed and the red fault indicator fl...

Страница 35: ... temperature see page 22 Time program see page 23 Time see page 28 No fuel With liquid propane gas Check the fuel reserves and re order if required With natural gas Open the gas shut off valve If necessary check with your gas supply utility Fault is displayed and the red fault indicator flashes Scan and acknowledge the type of fault see page 32 If necessary notify your heating contractor There is ...

Страница 36: ...control unit was changed by an external device e g extension EA1 No remedy is required Cause Remedy The heating program set at the control unit was changed by the Vitocom communication interface You can change the heating program Cause Remedy The time for a service as specified by your heating contractor has arrived Proceed as described on page 32 Controls Locked Out is Displayed External Hook up ...

Страница 37: ...pection and maintenance Inspection and maintenance of your heating system is recommended Regular maintenance ensures trouble free energy efficient environmentally responsible and safe heating Your heating system must be serviced by an authorised contractor at least every 2 years For this we advise you to arrange an inspection and maintenance contract with your local heating contractor Boiler Incre...

Страница 38: ...te Language Contrast Brightness Temperature unit Name for heating circ Main menu Factory default setting DHW temp setpoint Detailed scan options see following page DHW time program DHW circ time prog Party mode Economy mode Room temp setpoint Red room temp setpoint Operating program Heating time program Holiday program Heating curve Heating and DHW Only DHW Standby mode Zone circuit 3 Zone circuit...

Страница 39: ...mperature DHW tank prim pump DHW circ pump Flow switch Heating circuit 2 3 HC2 HC3 Heating program Operating status Time program Set room temperature Room temperature Set reduced room temp Set ext room temp Set party temp Slope Level Heating circ pump Mixing valves Flow temperature Return temp Holiday program Heating circuit 1 HC1 Heating program Operating status Time program Set room temperature ...

Страница 40: ...low temperature for the heating circuit without mixing valves is higher by a selected differential than the flow temperature for the heating circuits with mixing valves The illustrated heating curves apply with the following settings H Heating curve level 0 H Standard room temperature set value 68 F 20ºC Operating status In the heating program Heating and DHW the operating status changes from Stan...

Страница 41: ...by your heating contractor in the cold water pipe The safety valve opens automatically to prevent excess pressure in the DHW tank Solar circuit pump In conjunction with solar thermal systems The solar circuit pump delivers the cooled heat transfer medium from the DHW tank indirect coil to the collectors Set temperature Default temperature that should be reached e g set DHW temperature Summer mode ...

Страница 42: ...Vitodens 200 W B2HA B2HB 222 F B2TA B2TB Operating 5461 885 04 42 ...

Страница 43: ...43 5461 885 04Vitodens 200 W B2HA B2HB 222 F B2TA B2TB Operating ...

Страница 44: ...Technical information subject to change without notice Printed on environmentally friendly recycled and recyclable paper 5461 885 04 Vitodens 200 W B2HA B2HB 222 F B2TA B2TB Operating ...

Отзывы: