82
Pumps and other components
Pump/component
Parameter
Setting
Heating circuit pump
"System definition"
Ó
"System scheme 7000"
■ With heating circuit A1/
HC1 (for heating circuit
without mixer)
or
■ With heating circuit M2/
HC2 (for heating circuit
with mixer)
DHW circulation pump
Extended menu:
"Time program DHW cir-
culation"
Set time program
Extension kit, mixer for
heating circuit M2/HC2
"System definition"
Ó
"System scheme 7000"
Note
Set rotary switch S1 in the
extension kit to "2" (see ex-
tension kit installation in-
structions).
Remote control
For the heating/cooling cir-
cuit:
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
"1"
Note
Set coding on the Vitotrol for
heating circuit allocation
(see Vitotrol installation in-
structions).
For a separate cooling cir-
cuit:
"Cooling"
Ó
"Remote control cooling
circ 7116"
"1"
"Cooling"
Ó
"Ranking room temp.
sensor separate cooling
circuit 7106"
"0"
F16
"1"
A1/HC1
"2"
M2/HC2
"4"
SKK
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5546 699 GB
Содержание AWT-AC 241.A04
Страница 19: ...19 SLP N 9 11 aCH sG lJ 10 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 20: ...20 X20 2x 16 17 2x 12 14 18 13 15 Installation sequence Installing the internal unit cont 5546 699 GB...
Страница 21: ...21 2x 4x 4x 6x 21 19 20 22 Installation sequence Installing the internal unit cont 5546 699 GB Installation...
Страница 89: ...89 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5546 699 GB Service...
Страница 104: ...104 0010 0009 0007 0002 0004 0008 0001 0005 0003 0006 Parts lists internal unit Casing internal unit cont 5546 699 GB...
Страница 165: ...165 5546 699 GB...
Страница 166: ...166 5546 699 GB...
Страница 167: ...167 5546 699 GB...