PEX Press x ProPress

1. Square off tubing to proper length.

1a. Insert FostaPex tubing into prep tool. Push and turn tool until no more resistance is felt and tool  spins freely.

2. Slide press sleeve fully over end of tubing.

3. Insert press fitting into tubing and engage fully.

4. Check full tubing insertion at view hole of sleeve.

5. Engage press tool perpendicular over press sleeve and close tool jaws.

6. Start tool ratchet until automatic tool release occurs at proper compression force.

7. 

WARNING:

 

The connection is not leakproof when tool has been opened by emergency release. Connec-

tion must be remade using a new press sleeve.