Viega Multiplex Trio F Series Скачать руководство пользователя страница 8

Instructions for use Multiplex Trio F

GB

Install the profile seal and 

overflow unit. 

Screw the fastening flange 

with O-ring into the overflow 

unit.

Tighten the fastening flange.

Mount the seal onto the drain 

casing.

Installation example using 

steel bathtub (screw-in valve 

22.5 mm).

Installation example using a 

plastic bathtub (screw-in valve 

30 mm).

Insert screw-in valve with seal 

into the drain casing.

Tighten screw-in valve with 

assembly aid supplied.

Shorten the overflow pipe as 

required.

Mount overflow pipe and 

ensure sufficient insertion 

depth.

Insert inlet element.

Turn the external ring of the 

inlet element onto the screw 

heads of the screw-in valve.

Tighten fastening polygon 

screw slightly.

Place the cover plate onto the 

thread.

Screw the cover plate into the 

thread manually.

Mount cover rosette onto the 

overflow unit.

Loosen the connecting bend 

from the drain and connect 

on the water side.

Install the screw connection 

piece.

Mount connecting elbow 

onto the drain and tighten 

union nut by hand.

To close the valve cone: 

Turn the rotatable collar 

anticlockwise.

To open the valve cone: 

Turn the rotatable collar 

clockwise.

21

After assembly is complete, 

perform a leakage test.

E

Assembly steps

Unscrew the cover plate per 

hand.

Lift cover. 

Loosen internal polygon 

screw and remove inlet 

element.

Clean the inlet element under 

running water.

Loosen internal polygon 

screw on the valve cone.

Close the valve cone and 

hold this position with the 

rotatable collar. Remove valve 

cone.

Replace damaged seals. 

Clean drain casings as 

required.

To install, follow the same steps in reverse order!

F

Cleaning

The pipe interruptor prevents water 

from flowing back into the drinking 

water line when the bathtub is 

filled.

Installation diagram

Viega connecting set

with concealed pipe 

interruptor DN 20 design A2, 

DIN 1988-4 and DIN EN 1717

D

Function of pipe interruptor

8

Отзывы: